Cell Construction Sample Clauses

Cell Construction. Cell construction shall be in accordance with the Permit and VDEQ Regulations and all other regulations governing cell construction. Both Parties hereto recognize that the construction of the site is critical, and Green Ridge agrees to provide third party quality assurance of each liner system and allow a County representative to examine that work on a daily basis.
AutoNDA by SimpleDocs
Cell Construction. Cell construction shall be in accordance with Xxxxxxxx’ permit (up to a limit of 45 acres at any one time) with said limit applying only in areas being lined to accept waste, not areas being cleared, excavated, or on which soil is stockpiled). Cell construction shall include, but not be limited to, the following: a 1-foot compacted clay liner with a permeability of 10-7 cm/sec or less in combination with a 60 mil HDPE liner, 18 inches of sand with a leachate collection system, 80 mil HDPE liner covered with 18 inches of sand and a leachate collection system adequately designed to allow identification of the phase from which leachate is collected. Both parties hereto recognize that the construction of the site is critical, and Xxxxxxxx agrees to provide third party quality assurance of each liner system and allow a state and County representative to examine that work on a daily basis. The design of the site and the individual cells will be reviewed by County prior to its submission to the State and Xxxxxxxx will make all reasonable changes requested by County to that design. (See Addendum #5 II) In addition to solid waste, Xxxxxxxx will provide at its cost for residents of County the disposal of debris as required by applicable regulations.
Cell Construction. Section II, B. 7, shall be modified so that the second paragraph of that section shall read as follows: The design of the site and the individual cells will be reviewed by County prior to its submission to the State and Xxxxxxxx will make all reasonable changes requested by County to that design. Additionally, all redesigns and applications for permit revisions will be submitted to County and approved by it prior to submission to VDWM, such approval not to be unreasonably withheld.
Cell Construction. Cells shall be constructed to the grades established on the Final Grading Plans in accordance with the approved 2015 Operations Agreements Plans. The cell dimensions shall be in conformance with the typical Cell as shown on the plans in Section 3.3 (Sheet 10 incorporated by reference) unless otherwise approved by the Department. The cell shall be constructed by pushing the waste from the dumping pad to the cell location. Waste shall be spread and compacted on the working face of the cell from the bottom upward unless otherwise approved by the Department. The Contractor shall spread the waste in layers not to exceed two feet in thickness, then compact each layer with at least three passes of the compactor prior to adding the next layer. Bulky and large items in the waste stream shall be placed as low in the working face as possible. The finish surface of the waste shall be evenly graded, free of dips and humps, prior to placement of cover. Prior to cell construction, the Contractor shall scrape intermediate cover from the previous lift in the area where the current day’s waste will be placed and stockpile the dirt for later use. The intermediate cover shall be scraped such that no waste is exposed or mixed into the dirt to be stockpiled. If soil is mixed with small amount of waste it can be used a daily cover. The removal of the intermediate cover shall be in accordance with the required fire breaks shown in plans on Section 3.3 (Sheet 10 incorporated by reference) of contract. Contractor shall coordinate with the County and furnish all the necessary equipment and labor to install the Horizontal and Vertical Gas Collection System piping as shown on plans included in Section 3.3 (Sheets 9 & 11 incorporated by reference). Contractor shall protect pipes from damage during and after the installation. Contractor shall be solely responsible for any damages caused by Contractors' or customers' activities to said facilities. In the event the County repairs said damages, the County may deduct said expenses from any payments County is required to make to the Contractor under this Agreement (See Section 5.1 Compensation). Contractor shall provide labor and equipment costs that are directly associated with the construction of the Horizontal and Vertical Gas Collection System as described Section 3.3 (Sheet 9 & 11 incorporated by reference). County will need these costs for billing and reimbursement from an outside agency. Sufficient details must be provided to backup a...

Related to Cell Construction

  • Project Construction The Contractor agrees to provide continuous on-site supervision on each Job Order, while progress on the project is being accomplished. The Contractor’s Project Manager will ensure:

  • General construction 20.2.1. Binding Nature.............................................. 20.2.2. Entire Agreement............................................ 20.2.3. Governing Law............................................... 20.2.4. Indulgences Not Waivers..................................... 20.2.5. Titles Not to Affect Interpretation......................... 20.2.6.

  • Legal Construction If one or more of the provisions contained in this Agreement shall for any reason be held invalid, illegal, or unenforceable in any respect, such invalidity, illegality, or unenforceability shall not affect any other provisions and this Agreement shall be construed as if it did not contain the invalid, illegal, or unenforceable provision.

  • DAF Construction The DAF shall be designed and constructed in accordance with Good Utility Practice. Within one hundred twenty (120) Calendar Days after the Commercial Operation Date, unless the Developer and Connecting Transmission Owner agree on another mutually acceptable deadline, the Developer shall deliver to the Connecting Transmission Owner and NYISO “as- built” drawings, information and documents for the DAF, such as: a one-line diagram, a site plan showing the Large Generating Facility and the DAF, plan and elevation drawings showing the layout of the DAF, a relay functional diagram, relaying AC and DC schematic wiring diagrams and relay settings for all facilities associated with the Developer’s step-up transformers, the facilities connecting the Large Generating Facility to the step-up transformers and the DAF, and the impedances (determined by factory tests) for the associated step-up transformers and the Large Generating Facility. The Developer shall provide to, and coordinate with, Connecting Transmission Owner and NYISO with respect to proposed specifications for the excitation system, automatic voltage regulator, Large Generating Facility control and protection settings, transformer tap settings, and communications, if applicable.

  • Special Construction If, after an order is placed, Xxxxxxx finds that third-party special construction services are needed to build, configure or install any additional facilities and/or equipment necessary for Verizon to provide Access service, Verizon will notify the Customer of any such special construction charges. If Customer does not accept the special construction charges, Customer may terminate the order(s) affected by the special construction charges, with no cancellation fee(s).

  • ICIF Construction The ICIF shall be designed and constructed in accordance with Good Utility Practice. Within one hundred twenty (120) Calendar Days after the Commercial Operation Date, unless the Parties agree on another mutually acceptable deadline, Interconnection Customer shall deliver to Transmission Provider and Transmission Owner “as-built” drawings, information and documents for the ICIF, such as: a one-line diagram, a site plan showing the Generating Facility and the ICIF, plan and elevation drawings showing the layout of the ICIF, a relay functional diagram, relaying AC and DC schematic wiring diagrams and relay settings for all facilities associated with the Interconnection Customer’s step-up transformers, the facilities connecting the Generating Facility to the step-up transformers and the ICIF, and the impedances (determined by factory tests) for the associated step-up transformers and the Generating Facility. Interconnection Customer shall provide Transmission Provider and Transmission Owner with Interconnection Customer’s specifications for the excitation system, automatic voltage regulator, Generating Facility control and protection settings, transformer tap settings, and communications, if applicable.

  • New Construction If this contract is for a Property that is newly constructed and the new construction option is selected, coverage begins on day one (1) of month thirteen

  • Contract Construction 6.27.1 The parties acknowledge that each party and its counsel have reviewed this CONTRACT and that the normal rule of construction to the effect that any ambiguities are to be resolved against the drafting party shall not be employed in the interpretation of this CONTRACT or any amendment or exhibits hereto.

  • ADDITIONAL CONSTRUCTION The Promoter undertakes that it has no right to make additions or to put up additional structure(s) anywhere in the Project after the building plan has been approved by the competent authority (ies) except for as provided in the Act.

  • Agreement Construction Headings or captions to the provisions of this Agreement are solely for the convenience of the parties, are not part of this Agreement, and shall not be used to interpret or determine the validity of this Agreement. Any ambiguity in this Agreement shall not be construed against the drafter, but rather the terms and provisions hereof shall be given their reasonable interpretation.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!