Prior to Construction. At least five (5) business days prior to the commencement of construction, Lessee shall deliver to Lessor the following:
Prior to Construction. At least 5 days prior to the commencement of construction, Tenant shall deliver to Landlord the following:
Prior to Construction. Ensure that copies of manufacturers’ certification letters including those from others (e.g. consulting engineer, owner, etc.) for any AIS products to be used in the project is in the project file on site prior to installation.
Prior to Construction. Applicant shall submit a letter of intent to provide service from all utility companies planned for the subdivision. This should include gas, power, cable, internet and phone services. Applicant shall provide a letter of approval from North Unit Irrigation District & the Bureau of Reclamation, if applicable, for prior to approval of the subdivision plans. Formal plans, reports and specifications to be submitted for all construction. Applicant shall submit as-built plans (11”x17” - Hard Copy and Electronic – ACAD & PDF electronic files) as sections of work are completed. Wastewater system plans to be submitted to and approved by the City of Madras and by DEQ (only pump/lift station and forcemain for DEQ). Once the final plans are approved, schedule a pre-construction meeting with the City of Madras Public Works Department. The plan review process does not begin until a complete submittal is submitted to the City. A complete submittal includes the following:
1. Construction plans and specifications that conform to applicable ordinances, standards and Land Use Decision;
2. Storm drainage report that follows the steps outlined in Section 4 of these standards.
3. Sewer calculations;
4. Fire flow analysis;
5. Full QA permit fee deposit per resolution schedule and Public Works approved cost estimate for public improvements. If any of the items are missing, the submittal will be deemed incomplete and the review will be put on hold pending receipt of the missing documentation; and
6. Any capacity analysis reports and mitigation measures. After public improvement construction plans are approved by the City and prior to construction starting, attend a preconstruction meeting with the City of Madras Public Works Department. A construction schedule is to be submitted by the contractor at the preconstruction meeting along with contact information (including emergency contact phone numbers) provided to the City. The Public Works Department will outline requirements such as work days, hours, haul routes, dust & weed abatement requirements and other conditions for conformance to City Ordinances and policies. All other agency permits and fees (i.e. State, County) are to be gathered and submitted to the City prior to the start of construction.
Prior to Construction. Applicant shall submit a letter of intent to provide service from all utility companies planned for the subdivision. This should include gas, power, cable, internet and phone services. Applicant shall provide a letter of approval from North Unit Irrigation District & the Bureau of Reclamation, if applicable, for prior to approval of the subdivision plans. Formal plans, reports and specifications to be submitted for all construction. Applicant shall submit as-built plans (11”x17” - Hard Copy and Electronic – ACAD & PDF electronic files) as sections of work are completed. Wastewater system plans to be submitted to and approved by the City of Madras and by DEQ (only pump/lift station and forcemain for DEQ). Once the final plans are approved, schedule a pre-construction meeting with the City of Madras Public Works Department. The plan review process does not begin until a complete submittal is submitted to the City. A complete submittal includes the following:
1. Construction plans and specifications that conform to applicable ordinances, standards and Land Use Decision.
2. Storm drainage report that follows the steps outlined in Section 4 of these standards.
3. Sewer calculations.
Prior to Construction. Prior to any operations or construction at the Premises, Tenant must secure the Landlord's written approval of the Final Drawings per Section 2.2 of this Exhibit "C". At least five (5) working days prior to the commencement of construction, Tenant shall deliver to Landlord the following which shall be subject to Landlord's approval:
Prior to Construction. All sediment and erosion control measures will be installed by the contractor. The measures include the following: Storm drain inlets will be protected. Large diameter fiber rolls (straw wattles) will be placed around proposed work areas. Silt fencing will be placed as needed. A site entrance and exit will be established to avoid track out. The site will be evaluated for areas that have potential for inadvertent release of fluids (dry and cracked soils) and an inventory of proper drilling fluids and equipment will be on site to deal with the potential problem areas. Containment areas will be set up for equipment, drilling fluids and cutting refuge. Containment areas consist of some type of plastic sheathing formed with straw xxxxxxx to form a pit like area. Spill kits and cleanup materials, as described in Section 4.0.2.4 Spill Kit Equipment, will be available on site prior to any construction activities. The BMPs, emergency spill kit, and the Frac-Out kit will be staged nearby for immediate spill response.
Prior to Construction. EROSION AND SEDIMENT CONTROL (ESC) MEASURES WILL BE IMPLEMENTED PRIOR TO, AND MAINTAINED DURING CONSTRUCTION PHASES, TO PREVENT ENTRY OF SEDIMENT INTO WATER. ALL DAMAGED EROSION AND SEDIMENT CONTROL MEASURES SHOULD BE REPAIRED OR REPLACED WITHIN 48 HOURS OF INSPECTION OF BOTH.
Prior to Construction. The contractor must provide a detailed Maintenance Operation Procedure describing step by step the work to be performed in the building. The MOP should highlight risks (i.e. dust, debris, safety, etc.) and list corresponding proposed mitigation plans for each risk.
Prior to Construction. The Contractor shall submit the following documents to the Engineer prior to the Pre-Construction Conference specified in GP-14: