Cooling Tower Sample Clauses

Cooling Tower. The cooling tower shall be protected by a dry pipe sprinkler system furnished and installed for moderate hazard in accordance with the requirements of NFPA-13. If a concrete structure is provided, no fire protection is needed or supplied.
AutoNDA by SimpleDocs
Cooling Tower. In the event Tenant conducts business in any portion of the Demised Premises during hours other than regular business hours, Landlord shall, upon reasonable advance notice, operate the Building's cooling tower and such other equipment and machinery as shall enable Tenant to cool the Premises. Tenant shall reimburse Landlord for Landlord's cost of such service upon rendition of a bill xxxrefor, at a rate equal to Landlord's actual cost therefor, plus 15%.
Cooling Tower i. OC Public Works/Facilities Operation personnel will make a twice weekly check of the cooling tower water to determine the effectiveness of the treatment to control scale, algae, fungi and bacteria free operation and equipment corrosion protection, unless there is an issue which requires more frequent testing. Tests include PH, total hardness, total alkalinity, conductivity, free and total halogen and inhibitor levels.
Cooling Tower. Supply and Install a Cooling Tower (pad mounted) outside the production building. • Evapco USS-112-312 1200 USGPM from 95F to 85F WBT, or equivalent • Sump • Dual pumps • Flow meter • Cooling tower should have two fans and two pumps
Cooling Tower. The cooling tower will circulate 1200 gpm for a demonstrated period of 60 minutes as measured by a flow meter with all plant users in cooling mode (minimal pressure drop through system). During this same period, it will demonstrate the capacity to cool water from 95 to 87 F with an ambient WBT of 85 F at full flow. This will be determined by actual measurements and determination of capacity using standard charts.
Cooling Tower vii. Oil, grease and clean fan motors and bearings.
Cooling Tower. The Contractor shall operate, repair and maintain the cooling tower, Marley model #NC8405SAN1BMF, IAW the manufacturer’s maintenance manual and the maintenance schedule at Section J, Technical Exhibit 3.7. When faults are encountered or discovered, the Contractor shall initiate repair IAW priorities and timelines at paragraph C.5.2.3.
AutoNDA by SimpleDocs
Cooling Tower. If any one of the chiller types is water cooled, then a cooling tower will appear in the diagram. Click on the tower to define its properties. One of the properties is the number of cells. When you close the cooling tower form, the number of cells changes on the diagram. All cells are assumed to be the same. When you define the tower properties, including size, you are specifying information for a single cell. ▪ Pumps. Both chilled water and hot water supply pumps are specified by clicking on the pump icons. The information entered is for the secondary chilled water pumps only (the pumps that circulate water through the building coils). The primary pumps are specified when you define the chiller. The hot water pumps, on the other hand, should include the pressure drops (head) through the boilers and associated piping as well as the building coils. ▪ Electric Chiller Types. Click on a chiller to define its properties. Boilers. Click on a boiler to define its properties.
Cooling Tower. ‌ The cooling tower form can be activated from either the Equipment Editor, Central Plant Editor or the Water Loop HP Editor. The form works a little differently depending on how it is activated. These differences are described below. To activate: ▪ From the Central Plant Editor or the Water Loop HP Editor, (1) check Cooling Tower and (2) click on the cooling tower icon. ▪ From the Equipment Editor, (1) choose Cooling Tower from the Equipment Type drop-down list box, (2) select a cooling tower from the Templates list box, and (3) click the Define Template command button. Alternatively you can double click on a cooling tower in the Templates list box. The cooling tower form is organized on two folders labeled Specification and Curves. When opened from the Central Plant Editor, the Curves folder is for information only.
Cooling Tower. Replacement Center – there is no energy savings guarantee for this measure.