Cooling Tower Sample Clauses

Cooling Tower. The cooling tower shall be protected by a dry pipe sprinkler system furnished and installed for moderate hazard in accordance with the requirements of NFPA-13. If a concrete structure is provided, no fire protection is needed or supplied.
AutoNDA by SimpleDocs
Cooling Tower. In the event Tenant conducts business in any portion of the Demised Premises during hours other than regular business hours, Landlord shall, upon reasonable advance notice, operate the Building's cooling tower and such other equipment and machinery as shall enable Tenant to cool the Premises. Tenant shall reimburse Landlord for Landlord's cost of such service upon rendition of a bill therefor, at a rate equal to Landlord's actual cost therefor, plus 15%.
Cooling Tower. Supply and Install a Cooling Tower (pad mounted) outside the production building. • Evapco USS-112-312 1200 USGPM from 95F to 85F WBT, or equivalent • Sump • Dual pumps • Flow meter • Cooling tower should have two fans and two pumps
Cooling Tower. The cooling tower will circulate 1200 gpm for a demonstrated period of 60 minutes as measured by a flow meter with all plant users in cooling mode (minimal pressure drop through system). During this same period, it will demonstrate the capacity to cool water from 95 to 87 F with an ambient WBT of 85 F at full flow. This will be determined by actual measurements and determination of capacity using standard charts.
Cooling Tower i. OC Public Works/Facilities Operation personnel will make a twice weekly check of the cooling tower water to determine the effectiveness of the treatment to control scale, algae, fungi and bacteria free operation and equipment corrosion protection, unless there is an issue which requires more frequent testing. Tests include PH, total hardness, total alkalinity, conductivity, free and total halogen and inhibitor levels. ii. Equipment and chemical protection against scale and corrosion shall contain all of the following: a) PBTC/HEDP Phosphonate (to provide anodic and cathodic mild steel corrosion protection) b) Benzotriazole or Tolyltriazole (TT or BZT) (to provide copper corrosion protection c) High Stress Polymer (to provide calcium, iron and silt control), Polymer shall be non-foaming and non-Ionic d) Fluoresced inert and active trace element (to facilitate ease of testing). Product shall not contain any molybdenum (due to the County’s desire for no heavy metal discharge)
Cooling Tower. Landlord has represented to that, for the purposes of the Lease and Landlord's recapture of its costs with respect to the Cooling Tower, the cost of the Cooling Tower was no less than $250,000. Accordingly, Landlord and Tenant have agreed that Tenant shall reimburse Landlord for such cost in equal monthly installments based upon an assumed useful life for the Cooling Tower of 20 years and an interest rate of 9%. Landlord and Tenant agree that the resulting monthly payment is $2,249.31, which amount is payable on the first day of each month from March 1, 1998 until the earlier of (i) the expiration or cancellation of the term of the Lease, as renewed or extended from time to time, or (ii) February 28, 2018. Landlord acknowledges that, as of the date of this Fourth Amendment, Tenant has made such monthly payments that were due during the period from March 1, 1998 through December 1, 1998.
Cooling Tower. A natural draft cooling tower with closed-loop cooling water systems will be provided to serve Units 1 and 2 of the Xxxxxxx County Generating Station. The purpose of the cooling tower is to transfer to the atmosphere the heat absorbed by water circulating through the condensers of Generating Units 1 and 2, which condense low pressure steam discharged from steam-driven turbines. The closed-loop system with cooling tower is designed to minimize the release of heated waters (thermal pollution) to the Ohio River and is required to be installed in order to conform to applicable water pollution control regulations. The described water pollution control and abatement facility consists of the natural draft cooling tower, pumps, circulating water systems, water pipes, motors, blow-down system, structural supports and functionally related and subordinate equipment and facilities.
AutoNDA by SimpleDocs
Cooling Tower. Landlord, at its cost and expense, shall as soon as possible after the execution of this Amendment, install a cooling tower for the exclusive use of Tenant's computer facilities. Said cooling tower shall include two (2) twenty ton dry coolers with pumps and conduits of sufficient size to accommodate Tenant's current needs and reasonable expansion as outlined in option C to Landlord by letter dated December 5, 1996, copy of which is attached hereto."
Cooling Tower. Replacement Center – there is no energy savings guarantee for this measure.
Cooling Tower. If any one of the chiller types is water cooled, then a cooling tower will appear in the diagram. Click on the tower to define its properties. One of the properties is the number of cells. When you close the cooling tower form, the number of cells changes on the diagram. All cells are assumed to be the same. When you define the tower properties, including size, you are specifying information for a single cell. ▪ Pumps. Both chilled water and hot water supply pumps are specified by clicking on the pump icons. The information entered is for the secondary chilled water pumps only (the pumps that circulate water through the building coils). The primary pumps are specified when you define the chiller. The hot water pumps, on the other hand, should include the pressure drops (head) through the boilers and associated piping as well as the building coils. ▪ Electric Chiller Types. Click on a chiller to define its properties.