Metered Flow Rates in Error Sample Clauses

Metered Flow Rates in Error. If, for any reason, any Measurement Facilities are (i) out of adjustment, (ii) out of service or (iii) out of repair and the total calculated flow rate through each meter is found to be in error by an amount of the magnitude described in Section 9.3, the total quantity of Saltwater delivered shall be determined in accordance with the first of the following methods which is feasible: (a) by using the registration of any mutually agreeable check metering facility, if installed and accurately registering (subject to testing as provided for in Section 9.3); (b) where multiple meters exist in series, by calculation using the registration of such meter equipment; provided that they are measuring Saltwater from upstream and downstream headers in common with the faulty metering equipment, are not controlled by separate regulators and are accurately registering; (c) by correcting the error by re-reading of the official meter, or by straightforward application of a correcting factor to the quantities recorded for the period (if the net percentage of error is ascertainable by calibration, tests or mathematical calculation); or (d) by estimating the quantity, based upon deliveries made during periods of similar conditions when the meter was registering accurately.
AutoNDA by SimpleDocs
Metered Flow Rates in Error. If, for any reason, any Measurement Facilities used in measuring or checking the measurement of volumes of Fresh Water or Produced Water under this Agreement are (i) out of adjustment, (ii) out of service, or (iii) out of repair and the total calculated flow rate through each meter run is found to be in error in excess of two percent (2%) of the adjusted flow rate as described in Section 10.3, the total volumes of Fresh Water or Produced Water, as applicable, made available shall be determined in accordance with the first of the following methods which is feasible: (a) By using the registration of any mutually agreeable check metering facility, if installed and accurately registering (subject to testing as provided for in Section 10.3); (b) Where multiple meter runs exist in series, by calculation using the registration of such meter run equipment; provided that they are measuring Fresh Water or Produced Water, as applicable, in common with the faulty metering equipment, are not controlled by separate regulators, and are accurately registering; (c) By correcting the error by re-reading of the official data, or by straightforward application of a correcting factor to the volumes recorded for the period (if the net percentage of error is ascertainable by calibration, tests or mathematical calculation); or (d) By estimating the volumes, based upon volumes made available during periods of similar conditions when the meter was registering accurately.
Metered Flow Rates in Error. If, for any reason, any Measurement Facilities used in measuring or checking the measurement of volumes of Fresh Water under this Agreement are (i) out of adjustment, (ii) out of service, or (iii) out of repair and the total calculated flow rate through each meter run is found to be in error in excess of two percent (2%) of the adjusted flow rate as described in Section 12.3(b), the total volumes of Fresh Water made available shall be determined in accordance with the first of the following methods which is feasible: (a) By using the registration of any mutually agreeable check metering facility, if installed and accurately registering (subject to testing as provided for in Section 12.3), or Producer’s or its hydraulic fracturing contractor’s data regarding Fresh Water received at the Fresh Water Delivery Points, taken together with Antero Water’s data regarding the amount of such Fresh Water delivered that consisted of Treated Waste Water; (b) Where multiple meter runs exist in series, by calculation using the registration of such meter run equipment; provided that they are measuring Fresh Water in common with the faulty metering equipment, are not controlled by separate regulators, and are accurately registering; (c) By correcting the error by re-reading of the official data, or by straightforward application of a correcting factor to the volumes recorded for the period (if the net percentage of error is ascertainable by calibration, tests or mathematical calculation); or (d) By estimating the volumes, based upon volumes made available during periods of similar conditions when the meter was registering accurately.
Metered Flow Rates in Error. If, for any reason, any measurement equipment is (i) out of adjustment, (ii) out of service, or (iii) out of repair, and, in each case, a Material Measurement Error exists as a result thereof, the total quantity of Gas delivered shall be determined in accordance with the first of the following methods which is feasible: (a) by using the registration of any mutually agreeable check metering facility, if installed and accurately registering (subject to testing as provided for in Section 5.4); (b) where multiple meter runs exist in series, by calculation using the registration of such meter run equipment; provided that they are measuring Gas from upstream and downstream headers in common with the faulty metering equipment, are not controlled by separate regulators, and are accurately registering; or (c) by estimating the quantity, based upon deliveries made during periods of similar conditions when the meter was registering accurately.
Metered Flow Rates in Error. If, for any reason, any Measurement Facilities are out of adjustment, out of service or out of repair and the total calculated flow rate through each meter is found to be in error by an amount of the magnitude described in Section 9.3(b), the total quantity of Saltwater delivered shall be determined in accordance with the first of the following methods which is feasible: (a) by using the registration of any mutually agreeable check metering facility, if installed and accurately registering (subject to testing as provided for in Section 9.3); (b) where multiple meters exist in series, by calculation using the registration of such meter equipment; provided that they are measuring Saltwater from upstream and downstream headers in common with the faulty metering equipment, are not controlled by separate regulators and are accurately registering; (c) by correcting the error by re-reading of the official meter, or by straightforward application of a correcting factor to the quantities recorded for the period (if the net percentage of error is ascertainable by calibration, tests or mathematical calculation); or (d) by estimating the quantity, based upon deliveries made during periods of similar conditions when the meter was registering accurately.
Metered Flow Rates in Error. If, for any reason, any Measurement Facilities are (a) out of adjustment, (b) out of service, or (c) out of repair and the total calculated flow rate through each meter run is found to be in error by an amount of the magnitude described in Section 11.5, the total quantity of Gas delivered shall be determined in accordance with the first of the following methods which is feasible:
Metered Flow Rates in Error. If, for any reason, any Measurement Facilities used in measuring or checking the measurement of volumes of raw Fresh Water under this Agreement are (i) out of adjustment, (ii) out of service, or (iii) out of repair and the total calculated flow rate through each meter run is found to be in error in excess of two percent (2%) of the adjusted flow rate as described in (a) By using the registration of any mutually agreeable check metering facility, if installed and accurately registering (subject to testing as provided for in Section 12.3), or Producer’s or its hydraulic fracturing contractor’s data regarding Fresh Water received at the Fresh Water Delivery Points, taken together with Antero Water’s data regarding the amount of such Fresh Water delivered that consisted of Treated Waste Water; (b) Where multiple meter runs exist in series, by calculation using the registration of such meter run equipment; provided that they are measuring Fresh Water in common with the faulty metering equipment, are not controlled by separate regulators, and are accurately registering; (c) By correcting the error by re-reading of the official data, or by straightforward application of a correcting factor to the volumes recorded for the period (if the net percentage of error is ascertainable by calibration, tests or mathematical calculation); or (d) By estimating the volumes, based upon volumes made available during periods of similar conditions when the meter was registering accurately.
AutoNDA by SimpleDocs
Metered Flow Rates in Error. If, for any reason, any measurement equipment is (i) out of adjustment, (ii) out of service, or (iii) out of repair, and, in each case, a Material Pg 19 of 45 Gas Gathering Agreement dated [__________] Between Alpine High Gathering LP (Gatherer) and [__________] (Producer) Measurement Error exists as a result thereof, the total quantity of Gas delivered shall be determined in accordance with the first of the following methods which is feasible: (a) by using the registration of any mutually agreeable check metering facility, if installed and accurately registering (subject to testing as provided for in Section 10.4); (b) where multiple meter runs exist in series, by calculation using the registration of such meter run equipment; provided that they are measuring Gas from upstream and downstream headers in common with the faulty metering equipment, are not controlled by separate regulators, and are accurately registering; or (c) by estimating the quantity, based upon deliveries made during periods of similar conditions when the meter was registering accurately.

Related to Metered Flow Rates in Error

  • Interest Rates and Letter of Credit Fee Rates Payments and Calculations (a) Interest Rates. Except as provided in Section 2.13(c) and Section 2.15(a), all Obligations (except for the undrawn portion of the face amount of Letters of Credit) that have been charged to the Loan Account pursuant to the terms hereof shall bear interest at a per annum rate equal to the lesser of (i) the LIBOR Rate plus the Applicable Margin, or (ii) the maximum rate of interest allowed by applicable laws; provided, that following notice to Borrower in accordance with Section 2.15(a) hereof, all Obligations that have been charged to the Loan Account pursuant to the terms hereof shall bear interest at a per annum rate equal, during the duration of the circumstances described in Section 2.15(a), to the lesser of (A) the Base Rate plus the Applicable Margin as calculated pursuant to Section 2.15(a) or (B) the maximum rate of interest allowable by applicable laws.

  • Sleeping Room Rate(s) A. The Contractor shall provide sleeping rooms to the Attendees at the following rate during the Program: i. For single occupancy room, $@@@.@@ per night per room. B. The Contractor agrees that it will waive all applicable taxes and surcharges for Attendees listed on the Master Account Approval List, pursuant to the Hotel/Motel Transient Occupancy Tax Waiver (Exemption Certificate for State Agencies) form signed by the Judicial Council and included in this Agreement in Exhibit H. C. The Contractor may xxxx tax and/or surcharges, and/or tourism fees, if any, in addition to as included in the sleeping room rate, as set forth in this provision. D. The Contractor shall extend the sleeping room rate to Attendees two (2) Days before the Program and two (2) Days after the Program based on availability.

  • PREVAILING WAGE RATES - PUBLIC WORKS AND BUILDING SERVICES CONTRACTS If any portion of work being Bid is subject to the prevailing wage rate provisions of the Labor Law, the following shall apply:

  • Overhead Rates The Engineer shall use the provisional overhead rate indicated in Attachment E. If a periodic escalation of the provisional overhead rate is specified in Attachment E, the effective date of the revised provisional overhead rate must be included. For lump sum contracts, the overhead rate remains unchanged for the entire contract period.

  • Service Level Expectations Without limiting any other requirements of the Agreement, the Service Provider shall meet or exceed the following standards, policies, and guidelines:

  • Uncontrollable Forces Tariff Provisions Section 14.1 of the CAISO Tariff shall be incorporated by reference into this Agreement except that all references in Section 14.1 of the CAISO Tariff to Market Participants shall be read as a reference to the Participating Generator and references to the CAISO Tariff shall be read as references to this Agreement.

  • Mileage Measurement Where required, the mileage measurement for LIS rate elements is determined in the same manner as the mileage measurement for V&H methodology as outlined in NECA Tariff No. 4.

  • Indirect Cost Rates The System Agency may acknowledge an indirect cost rate for Grantees that is utilized for all applicable Grant Agreements. For subrecipients receiving federal funds, indirect cost rates will be determined in accordance with applicable law including, but not limited to, 2 CFR 200.414(f). For recipients receiving state funds, indirect costs will be determined in accordance with applicable law including, but not limited to, TxGMS. Grantees funded with blended federal and state funding will be subject to both state and federal requirements when determining indirect costs. In the event of a conflict between TxGMS and applicable federal law or regulation, the provisions of federal law or regulation will apply. Grantee will provide any necessary financial documents to determine the indirect cost rate in accordance with the Uniform Grant Guidance (UGG) and TxGMS.

  • Long Term Cost Evaluation Criterion # 4 READ CAREFULLY and see in the RFP document under "Proposal Scoring and Evaluation". Points will be assigned to this criterion based on your answer to this Attribute. Points are awarded if you agree not i ncrease your catalog prices (as defined herein) more than X% annually over the previous year for years two and thr ee and potentially year four, unless an exigent circumstance exists in the marketplace and the excess price increase which exceeds X% annually is supported by documentation provided by you and your suppliers and shared with TIP S, if requested. If you agree NOT to increase prices more than 5%, except when justified by supporting documentati on, you are awarded 10 points; if 6% to 14%, except when justified by supporting documentation, you receive 1 to 9 points incrementally. Price increases 14% or greater, except when justified by supporting documentation, receive 0 points. increases will be 5% or less annually per question Required Confidentiality Claim Form This completed form is required by TIPS. By submitting a response to this solicitation you agree to download from th e “Attachments” section, complete according to the instructions on the form, then uploading the completed form, wit h any confidential attachments, if applicable, to the “Response Attachments” section titled “Confidentiality Form” in order to provide to TIPS the completed form titled, “CONFIDENTIALITY CLAIM FORM”. By completing this process, you provide us with the information we require to comply with the open record laws of the State of Texas as they ma y apply to your proposal submission. If you do not provide the form with your proposal, an award will not be made if your proposal is qualified for an award, until TIPS has an accurate, completed form from you. Read the form carefully before completing and if you have any questions, email Xxxx Xxxxxx at TIPS at xxxx.xxxxxx@t xxx-xxx.xxx

  • Supported wage rates Employees to whom this clause applies shall be paid the applicable percentage of the minimum rate of pay prescribed by this Agreement for the class of work which the person is performing according to the following schedule: * (Provided that the minimum amount payable shall be not less than $45 per week). Where a person’s assessed capacity is 10%, they shall receive a high degree of assistance and support.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!