Network Upgrade Charges Sample Clauses

Network Upgrade Charges. A. The Network Customer has confirmed the following supplemental Network Resources requiring Network Upgrades: 1. GRDA resource, 15MW from POR – GRDA, Source – GRDA to POD – SECI, Sink MKEC_WPEK , as more specifically identified in transmission request 74086234. Contingent upon the completion of required upgrades as specified below, designation of this network resource shall be effective on June 1, 2010 and remain effective through June 1, 2026. The requested service requires completion of the following aggregate study SPP-2008-AGP1 allocated network upgrades. The costs of these upgrades are allocated to the Network Customer but are partially base plan fundable in accordance with Section III.A. Attachment J of the Tariff. Upgrade Name Upgrade Description Transmission Owner Date Required in Service XXXXXX - ST XXXX 115KV CKT 1 Replace CTs and relays at Xxxxxx substation and St Xxxx substation MKEC 6/1/2010 ARCADIA (ARCADIA2) 345/138/13.8KV TRANSFORMER CKT 1 Accelerate Add 3rd 345/138KV Auto and convert the 345kV and 138kV to a breaker and a half configuration. OKGE 6/1/2010 ARCADIA - REDBUD 345KV CKT 3 Add eight mile 3rd 345 kV line from Redbud to Arcadia OKGE 6/1/2019 XXXXXX - MEMORIAL 138KV CKT 1 Change out wavetrap to 2000A OKGE 6/1/2019 EAST MANHATTAN - XXXXXXX ENERGY CENTER 230KV CKT 1 Rebuild existing line to 345 kV operated as 230 kV WERE 0/0/0000 XXXX XXXXXXXXX - XX XXXXXXXXX 230KV CKT 1 Replace Terminal Equipment WERE 6/1/2019 XXXXXXXX SOUTH - SEDGWICK COUNTY NO. 12 COLWICH 138KV CKT 1 Replace disconnect switches, wavetrap and CT WERE 6/1/2019 XXXXXX - XXXXX CENTER 115KV CKT 1 Replace CTs and relays at Xxxxxx substation and Xxxxx Center substation MKEC 6/1/2018 The requested service depends on and is contingent on completion of the following Reliability and Construction Pending upgrades. These upgrades costs are not assignable to the Network Customer. Upgrade Name Upgrade Description Transmission Owner Date Required in Service CLEARWATER - XXXX ENERGY CENTER WEST 138KV CKT 1 Rebuild 7.88 mile Xxxx-Clearwater WERE 6/1/2012 XXXXX - XXXXXX 345KV CKT 1 MIDW Build a new 345kV line from Xxxxx - Xxxxxx MIDW 6/1/2010 XXXXX - XXXXXX 345KV CKT 1 NPPD Build a new 345kV line from Xxxxx - Xxxxxx NPPD 6/1/2010 XXXXX 345/230 KV TRANSFORMER Add new 345/230 KV TRANSFORMER MIDW 6/1/2010 MEDICINE XXXXX - XXXXX 115KV CKT 1 Rebuild 26 mile line MKEC 6/1/2013 MEDICINE LODGE 138/115KV TRANSFORMER CKT 1 Accelerated Upgrade transformer MKEC 12/1/2011 SPEARVILLE - XXXXX 345...
AutoNDA by SimpleDocs
Network Upgrade Charges. System reinforcements may be required in the future to support the load forecasts. Future charges, if required, shall be in accordance with Section 32 of the Tariff.
Network Upgrade Charges. In addition to all other applicable charges, Network Customer shall pay remaining monthly revenue requirements of $48,083.80 from January 1, 2010 – January 1, 2012 for a total of $1,154,011.20 for remaining revenue requirements required for the Green Country Network Resource confirmed on transmission service requests 974790, 974791, 974793, 974797. The revenue requirement for American Electric Power transmission facility upgrade is $20,762.84/month for the Explorer Glenpool-Riverside Station 138kV upgrade. The revenue requirements for Oklahoma Gas and Electric’s transmission facility upgrades are $9015.88/month for the Beeline-Explorer Glenpool 138kV upgrade, and $18,305.08/month for the Explorer Glenpool-Riverside Station 138kV upgrade. These upgrades were required to provide firm Point-To-Point Service to Southwestern Public Service Company under transmission service requests 974790, 974791, 974793, 974797.
Network Upgrade Charges. A. The Network Customer has confirmed the following supplemental Network Resources requiring Network Upgrades: 1. Southwest Power Station #2 275MW from POR- SPA, Source- Southwest Power Station #2, POD-SPA, Sink-SPRM_SPA, as more specifically identified in transmission service request 1220082. Contingent upon the completion of required upgrades as specified below, designation of this resource shall be effective on October 1, 2010 and shall remain effective through October 1, 2050. The requested service depends on and is contingent on completion of the following aggregate study SPP-2007-AG1 allocated network upgrades. The costs of these upgrades are allocated to the Network Customer but are fully base plan fundable in accordance with Section III.A. Attachment J of the Tariff. a) Network upgrades on the Brookline – Junction 161kV Ckt. 1 facility by The Board of Public Utilities, Springfield, Missouri required by June 1, 2013. This upgrade consists of replacing 1,200 amp switches with 2,000 amp units and replace metering CTs at the Brookline Substation. Replace 1,200 amp switches with 2,000 amp units at the Junction Substation. The requested service depends on and is contingent on completion of the following Transmission Owner Reliability Upgrades resulting from the SPP Expansion Plan. These upgrades costs are not assignable to the Network Customer. Upgrade Name Upgrade Description Transmission Owner Date Required in Service NEERGARD - NORTON 69KV CKT 1 Transfer load & Reconductor 336.4 kcmil ACSR with 477 ACSS/TW SPRM 10/1/2010 2. Smoky Hills Wind 25MW from POR- WR, Source- XX.XX.XXXX0.XX, POD- SPA, Sink-SPRM_SPA, as more specifically identified in transmission service request 73315404. Contingent upon the completion of required upgrades as specified below, designation of this resource shall be effective on October 1, 2009 and shall remain effective through October 1, 2029. The requested service depends on and is contingent on completion of the following Transmission Owner Reliability and Construction Pending Upgrades. These upgrades costs are not assignable to the Network Customer. Upgrade Name Upgrade Description Transmission Owner Date Required in Service AUBURN ROAD (AUBRN77X) 230/115/13.8KV Add second Auburn 230-115 kV transformer. WERE 6/1/2013 Upgrade Name Upgrade Description Transmission Owner Date Required in Service TRANSFORMER CKT 2 SILOAM CITY - SILOAM SPRINGS 161KV CKT 1 Replace switches & jumpers @ AEP Siloam Springs. AEPW 6/1/2010 3. Smoky Hil...
Network Upgrade Charges. A. The Network Customer has confirmed the following supplemental Network Resources requiring Network Upgrades: 1. For service provided during the period October 1, 2006 – October 1, 2026, for the additional resource of 15MW of GRDA, as confirmed per Transmission Service Request 1121173 and 1121177, facility upgrades are required on the American Electric Power Explorer Glenpool-Riverside Station 138kV facility to be completed on or before June 1, 2009, Oklahoma Gas and Electric transmission facility upgrades for the Explorer Glenpool-Riverside Station 138kV upgrade to be completed on or before June 1, 2009, and facility upgrades for the Beeline-Explorer Glenpool 138kV facility to be completed on or before June 1, 2009. Cost allocation for these upgrades are fully funded pursuant to SPP OATT Attachment J, base plan funding criteria and not assignable to the transmission customer. For service provided during the period October 1, 2006 – October 1, 2026, for the additional GRDA resource of 15MW, the requested service is contingent upon completion of upgrades to the JEC- Swissvale 345kV facility by Westar Energy on or before June 1, 2011, the completion of the new Chamber Springs-Tontitown 345kV facility by American Electric Power on or before June 1, 2009, and the completion of upgrades to the Lacygne-Paola-West Xxxxxxx 345kV facility by Kansas City Power and Light on or before June 1, 2008. These upgrades are not assignable to the Transmission Customer. 2. WAPA Resource - 7 MW from POR – NPPD, Source – NPPD to POD – KCPL, Sink- KMEA_KCPL, as more specifically identified in transmission request 74436734. Contingent upon the completion of required upgrades as specified below, designation of this network resource shall be effective on October 1, 2012 and remain effective through October 1, 2017. The requested service depends on and is contingent on completion of the following Reliability and Construction Pending Projects. These upgrades costs are not assignable to the Network Customer. Upgrade Name Upgrade Description Transmission Owner Date Required in Service HITCHLAND INTERCHANGE 230/115KV TRANSFORMER CKT 1 Build Hitchland - Xxxxx 230kV and Hitchland Xxxxxxx 230kV SPS 8/1/2010 XXXXXXX - LEXINGTON 115KV CKT 1 Increase clearances to 100 Deg C and upgrade terminal equipment (PCB, DISC, WVTRP, CT, BUS) to effect higher rating. NPPD 12/1/2010 XXXXXXXX - XXXX XXXXXXX 345KV CKT 1 Upgrade Xxxxxxxx terminal equipment to 2000 amps XXXX 0/0/0000 XXX - Xxxxxx Xxxx 161kV ...
Network Upgrade Charges. The Dogwood resource identified in transmission service request 91119197 is contingent upon the completion of required upgrades as specified below; designation of this resource shall be effective on December 1, 2020 and shall remain effective through 6/1/2030. The requested service depends on and is contingent on completion of the following 2020-AG1- AFS-3 network upgrades specified below. Costs of these upgrades are not assignable to the Network Customer. Greenwood breaker replacements (143183) Replace 2 breakers, relays at Greenwood 161 kV substation KCPL 6/1/2021 Pleasant Hill breaker replacement and Lake Winnebago switch replacement (143184) Replace 2 breakers at Pleasant Hill 161 kV substation, replace 1 switch at Lake Winnebago substation KCPL 6/1/2021

Related to Network Upgrade Charges

  • Network Upgrades The Transmission Owner shall design, procure, construct, install, and own the Network Upgrades described in Attachment 6 of this Agreement. If the Transmission Owner and the Interconnection Customer agree, the Interconnection Customer may construct Network Upgrades that are located on land owned by the Interconnection Customer. Unless the Transmission Owner elects to pay for Network Upgrades, the actual cost of the Network Upgrades, including overheads, shall be borne initially by the Interconnection Customer.

  • Service Charges No service charge shall be made for any exchange or registration of transfer of Warrants.

  • System Upgrades The Connecting Transmission Owner shall procure, construct, install, and own the System Upgrade Facilities and System Deliverability Upgrades described in Attachment 6 of this Agreement. To the extent that design work is necessary in addition to that already accomplished in the Class Year Interconnection Facilities Study for the Interconnection Customer, the Connecting Transmission Owner shall perform or cause to be performed such work. If all the Parties agree, the Interconnection Customer may construct System Upgrade Facilities and System Deliverability Upgrades. 5.2.1 As described in Section 32.3.5.3 of the SGIP in Attachment Z of the ISO OATT, the responsibility of the Interconnection Customer for the cost of the System Upgrade Facilities and System Deliverability Upgrades described in Attachment 6 of this Agreement shall be determined in accordance with Attachment S of the ISO OATT, as required by Section 32.3.5.3.2

  • Software Upgrades All Software Releases (including all Error corrections made available pursuant to this Agreement) that RSA in its sole discretion: (a) deems to be logical improvements to the Software; (b) make generally available to all licensees of the Software; and (c) does not separately price or market.

  • Maintenance Charges 6.1 The maintenance services for the Said Plot / Said Complex/Said Building, as set out in Annexure T-IV to this Lease Deed, shall be provided by THE LESSOR or its nominees/ assigns, the estimated Maintenance Charges for which shall be calculated prorata of the super built up area of the Demised Premises to the total super built-up area of the Property. 6.2 The Maintenance Charges for such maintenance services shall be paid to THE LESSOR or its nominees/ assigns, in advance for each month, as per the xxxx(s)/ invoice(s) raised by THE LESSOR or its nominees/ assigns. 6.3 The Maintenance Charges shall be subject to deduction of Income Tax at source as applicable, from time to time. 6.4 Any other taxes/ duties/ charges/ cesses / levy(ies) etc. as applicable from time to time on Maintenance Charges including service tax shall be payable by THE LESSEE in addition to the Maintenance Charges mentioned hereinabove as and when demanded by THE LESSOR. 6.5 The Maintenance Charges shall be payable by the Due Date, in advance for each month in respect of which such Maintenance Charges would be payable. 6.6 The Maintenance Charges as specified in this Lease Deed are subject to increase of prices of diesel, gas, petroleum products and other consumables, electricity rates, taxes, wages and salaries, cost of annual maintenance contracts of lifts, DGs, HVAC supplies, transformers, panels etc. during the Lease Term and the Lease Renewal Term (if any). 6.7 After completion of a financial year (i.e. from 1st April of a calendar year to 31st March of the next calendar year), THE LESSOR or its nominees / assigns will provide THE LESSEE, within a reasonable time period, a third party auditor certificate of expenditure/ expenses towards maintenance charges incurred during such financial year. Any under-recovery by THE LESSOR or its nominees/assigns shall become payable by THE LESSEE to THE LESSOR or its nominees/assigns and any over-recovery by THE LESSOR or its nominees/assigns shall become refundable by THE LESSOR/ or its nominees/assigns to THE LESSEE. Any such payment by refund to THE LESSEE shall be without any interest and such payment shall be payable by either party within thirty (30) days of providing such third party auditor certificate and issuance of credit/ debit note (as applicable).

  • CONTRACT CHARGES The Contract Charges for the Services shall be structured using any of the following pricing mechanisms (as may be agreed by the Parties and set out in an SOW); Capped Time and Materials; Price per Story; Time and Materials; Fixed Price (to be used only for Services that are ancillary to software development services); or using such other pricing mechanism or combination of pricing mechanism thereof as may be agreed by the Parties. In consideration of the Supplier’s performance of its obligations under this Contract and in consideration of the specific services that are set out in an applicable SOW, the Customer shall pay the undisputed Contract Charges in accordance with the relevant SOW for the Release and the payment provisions set out at Clause 14 (Payment and VAT). The Customer shall, in addition to the Contract Charges and following delivery by the Supplier of an Invoice, pay the Supplier a sum equal to the VAT chargeable on the value of the Services supplied in accordance with this Contract. If at any time during this Contract Period the Supplier reduces its framework Prices for any Services which are provided under the framework Agreement (whether or not such Services are offered in a catalogue (if any) which is provided under the framework Agreement) in accordance with the terms of the framework Agreement, the Supplier shall immediately reduce the Contract Charges for such Services under this Contract by the same amount. The Supplier shall in any event ensure that the Contract Charges are at all times compliant and consistent with the charging structure set out in framework Schedule 8 (Charging Structure) and do not exceed the prices set out therein. Contract Charges:

  • Service Charge The Tenant must pay the Service Charge in accordance with Part 1 of Schedule 3. The Tenant must pay: VAT on any consideration in respect of a VAT Supply to the Tenant by the Landlord at the same time as the consideration is paid; and on demand VAT (and interest, penalties and costs where these are incurred because of anything the Tenant does or fails to do) charged in respect of any VAT Supply to the Landlord in respect of the Premises where that VAT is not recoverable by the Landlord from HM Revenue & Customs. The Tenant must not do anything that would result in the disapplication of the option to tax in respect of the Landlord’s interest in the Building. The Tenant must pay interest on the Rents and on all other sums not paid on or by the due date (or, if no date is specified, not paid within 10 Business Days after the date of demand). Interest will be payable at the Interest Rate for the period starting on the due date (or date of demand) and ending on the date of payment. The Tenant must pay on demand the Landlord’s costs (including legal and surveyor’s charges and bailiff’s and enforcement agent’s fees) and disbursements in connection with: any breach of the Tenant’s obligations in this Lease, including the preparation and service of a notice under section 146 of the 1925 Act; any application by the Tenant for consent under this Lease, whether that application is withdrawn or consent is granted or lawfully refused, except in cases where the Landlord is required to act reasonably and the Landlord unreasonably refuses to give consent; [and] [carrying out works to the Premises to improve their Environmental Performance where the Tenant, in its absolute discretion, has consented to the Landlord doing so; and]31 the preparation and service of a schedule of dilapidations served no later than six months after the End Date. Third party indemnity32 The Tenant must indemnify the Landlord against all actions, claims, demands made by a third party, all costs, damages, expenses, charges and taxes payable to a third party and the Landlord’s own liabilities, costs and expenses incurred in defending or settling any action, claim or demand in respect of any personal injury or death, damage to any property and any infringement of any right, in each case arising from: the state and condition of the Premises or the Tenant’s use of them; the exercise of the Tenant’s rights; or the carrying out of any Permitted Works. In respect of any claim covered by the indemnity in clause 4.7.1, the Landlord must: give formal notice to the Tenant of the claim as soon as reasonably practicable after receiving notice of it; provide the Tenant with any information and assistance in relation to the claim that the Tenant may reasonably require and the Landlord is lawfully able to provide, subject to the Tenant paying to the Landlord all costs incurred by the Landlord in providing that information and assistance; and mitigate its loss (at the Tenant’s cost) where it is reasonable for the Landlord to do so.

  • Network Upgrades and Distribution Upgrades The Participating TO shall design, procure, construct, install, and own the Network Upgrades and Distribution Upgrades described in Appendix A. The Interconnection Customer shall be responsible for all costs related to Distribution Upgrades. Unless the Participating TO elects to fund the capital for the Distribution Upgrades and Network Upgrades, they shall be solely funded by the Interconnection Customer.

  • Transportation Charges The cost of transporting Employees and Material necessary for the Mining Operations.

  • Maintenance Outages If Seller reasonably determines that it is necessary to schedule a Maintenance Outage, Seller shall notify Buyer of the proposed Maintenance Outage at least five (5) days before the outage begins (or such shorter period to which Buyer may reasonably consent in light of then existing conditions). Upon such notice, the Parties shall plan the Maintenance Outage to mutually accommodate the reasonable requirements of Seller and the service obligations of Buyer; provided, however, that, unless Buyer otherwise consents, such consent not to be unreasonably withheld, no Maintenance Outage may be scheduled between the hour ending 0700 through the hour ending 2200, Monday through Saturday, during the time period commencing on May 15 and concluding on September 15. Notice of a proposed Maintenance Outage shall include the expected start date and time of the outage, the amount of Capacity of the Facility that will not be available, and the expected completion date and time of the outage. Seller shall give Buyer notice of the Maintenance Outage as soon as Seller determines that the Maintenance Outage is necessary. Buyer shall promptly respond to such notice and may request reasonable modifications in the schedule for the outage. Seller shall use all reasonable efforts to comply with any request to modify the schedule for a Maintenance Outage. Seller shall notify Buyer of any subsequent changes in Capacity available to Buyer or any changes in the Maintenance Outage completion date and time. As soon as practicable, any notifications given orally shall be confirmed in writing. Seller shall take all reasonable measures and exercise its best efforts in accordance with Prudent Electrical Practices to minimize the frequency and duration of Maintenance Outages.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!