Datacenter. Fire detection - State-of-the-art fire detection and Argon distinguishers - Direct connection to the fire department ensure an immediate fire extinction. - Air condition - Redundant air conditionings with free cooling enable sustainbable - Environment friendly cooling of the data centers - UPS in separate protected environment
Datacenter. Grantor shall use commercially reasonable efforts to, (i) maintain the temperature in the Conditioned Premises within the range specified in Item 4(a) of Exhibit “F-I”, Exhibit “F-II”, and Exhibit “F-III”, during the applicable periods, as described therein, and (ii) maintain the relative humidity in the Conditioned Premises within the range specified in Item 4(b) of Exhibit “F-I”, Exhibit “F-II” , and Exhibit “F-III”, during the applicable periods, as described therein.
Datacenter. Suite 140 located on the first (1st) floor of the Building approximately as depicted on Exhibit “A” (the “Datacenter”).
Datacenter. The DPGS system utilizes a leased facilities and capacity in a highly secure, fault tolerant, enterprise-class data center, designed to provide 100% uptime. Maintenance of the facilities, operation and management of the datacenter is outsourced to Databank LLC, 400 X. Xxxxx St., Dallas, Texas 75202, in the former home of the Dallas Federal Reserve Bank, which enables DPGS and the Company to benefit from a state-of-the art infrastructure facility, while not having to commit significant resources, capital or human, to the build-out and ownership of the infrastructure. The ability to expand capacity and scalability requirements (space, power, networking and redundancy capability) is virtually without limitation. Security of the installed assets, information, applications and client data are of paramount importance. Security at the Datacenter is provided on a 24/7/365 basis. Card access is required to gain access, along with biometric hand scanning upon entry, and annual SAS 70 Audits are performed to ensure the delivery of services at the highest possible levels. Uptime of the website is essential for the Company to provide consistent and reliable services to our users. To ensure this level of service, our systems have reliable UPS/Backup Generators and reliable utility power. The UPS/Backup Generator power supply provides: true A+B power configurations, all UPS and Generator deployments provide N+1 redundancy, 800KVA MGE UPS Systems, 1200 KVA CAT UPS Systems, 2.0 megawatt generators, 1.5 megawatt generators. There are six utility feeds from the CBD grid, N+3 Transformers with ATS switches and the feeds to building are concrete encased. Cooling systems employ 3,500 Ton cooling tower capacity, 30 Xxx Xxxxxxx XXXX Xxxxx, designed with N+1 redundancy and 80,000 gallon reserve make-up water tank.
Datacenter. This section of the SLA covers operational status of the datacenters including electrical power, environmental systems, and physical security. 9000 Xxxxxxxxx Xxxxx, Xxxxx 000 | Sxx Xxxxxxx, XX 00000 PH: 210.447.4000 | FX: 210.447.4400
1.1.1. Power Availability — A/C Power systems in the datacenter are designed to run uninterrupted, including during a utility power outage. A/C power to the outbound port on Customer serving power distribution unit (PDU) is guaranteed to be available 100% of the time in a calendar month.
1.1.2. HVAC Quality and Availability (Heating Ventilation and Air Conditioning) — Target ambient room temperature will be [**] Degrees F in the server area of the datacenter. Ambient room temperature will not vary by more than +/- [**] degrees. Relative humidity will be targeted for [**]% in the server area. Relative humidity will not vary by more than +/- [**]%. Rackspace guarantees that the HVAC facilities will provide adequate cooling [**]% of the time in a calendar month. 9000 Xxxxxxxxx Xxxxx, Xxxxx 000 | Sxx Xxxxxxx, XX 00000 PH: 210.447.4000 | FX: 210.447.4400
Datacenter. A n y destination IP address outside o f the Akamai network used a s a source location for Customer content (and would not include any Akamai IP address or Service, such as Akamai NetStorage).
Datacenter. The DEPO system utilizes a highly secure, fault tolerant, enterprise-class data center, designed to provide 100% uptime. Maintenance of the facilities, operation and management of the Datacenter is outsourced to Databank LLC, 000 X. Xxxxx St., Dallas, Texas 75202, in the former home of the Dallas Federal Reserve Bank, which enables DEPO to benefit from a state-of-the art infrastructure facility, while not having to commit significant resources, capital or human, to the build-out and ownership of the infrastructure. The ability to expand our capacity and scalability requirements (space, power, networking and redundancy capability) is virtually without limitation. Security of the installed assets, information, applications and client data are of paramount importance. Security at the Datacenter is provided on a 24/7/365 basis. Card access is required to gain access, along with biometric hand scanning upon entry, and annual SAS 70 Audits are performed to ensure the delivery of services at the highest possible levels. Uptime of the website is essential for DEPO to provide consistent and reliable services to our users. To ensure this level of service, our systems have reliable UPS/Backup Generators and reliable utility power. The UPS/Backup Generator power supply provides: true A+B power configurations, all UPS and Generator deployments provide N+1 redundancy, 800KVA MGE UPS Systems, 1200 KVA CAT UPS Systems, 2.0 megawatt generators, 1.5 megawatt generators. There are six utility feeds from the CBD grid, N+3 Transformers with ATS switches and the feeds to building are concrete encased. Cooling systems employ 3,500 Ton cooling tower capacity, 00 Xxx Xxxxxxx XXXX Xxxxx, designed with N+1 redundancy and 80,000 gallon reserve make-up water tank.
Datacenter. Suite 130 of the Building depicted on Exhibit “A” attached hereto.
Datacenter. Cleura guarantees 99.95% uptime on the power and HVAC services serving our technical platform. For dedicated/bare metal and co-location customers, redundant power supplies are mandatory to be covered by this guarantee. SLA only covers Cleura facilities. Any external equipment owned by the customer is not covered by the SLA. Cleura guarantees 99.95% availability of infrastructure hardware, including compute, network, control and storage nodes. Any hardware included in our core infrastructure is designed to be redundant. Dedicated/Bare metal servers and co-location is not included and are treated differently below. For dedicated servers and bare metal hardware, we guarantee the function- ing of all server hardware components we provide, and will replace any failed component at no cost. This includes, but is not limited to, servers, mother- board, memory, hard drives, raid controllers, NIC cards and firewalls. The replacement will be initiated as soon as hardware is determined to be the cause of the problem. The new hardware shall be in place within four hours. Colocated and customer provided equipment is excluded from the Dedicated/Bare metal SLA. Cleura offers the following terms for rack space provided to clients – referred to as “co-location”. Client is responsible for hardware and will need to arrange for replacement, unless other has been agreed with Cleura. To be entitled to our network guarantee, a fully redundant solution is required on all containing elements.
Datacenter. This section of the SLA covers operational status of the datacenters including electrical power, environmental systems, and physical security. 0000 Xxxxxxxxx Xxxxx, Xxxxx 000 | Xxx Xxxxxxx, XX 00000 PH: 210.447.4000 | FX: 210.447.4400
1. Power Availability — A/C Power systems in the datacenter are designed to run uninterrupted, including during a utility power outage. A/C power to the outbound port on Customer serving power distribution unit (PDU) is guaranteed to be available 100% of the time in a calendar month. Remedy: In the event that Rackspace fails to provide A/C power [**]% of the time in a calendar month and such failure directly and adversely affects Customer’s hosted configuration, Customer is entitled to a credit in the amount of [**]% of the monthly recurring fee for the first [**] of power outage, [**]% of the monthly recurring fee for the second [**] of power outage, [**]% of the monthly recurring fee for the third [**] of power outage, [**]% of the monthly recurring fee for the fourth [**] of power outage, and an additional [**]% of the monthly recurring fee if power outages exceed [**] in a calendar month (up to [**]% of Customer’s monthly recurring fee for the month in which the outage(s) occur) for the affected component(s).