Developer and Connecting. Transmission Owner agree to report to each other in writing as soon as practical all accidents or occurrences resulting in injuries to any person, including death, and any property damage arising out of this Agreement.
Developer and Connecting. Transmission Owner shall each cooperate with the other in the inspection, maintenance, and testing of control or power circuits that operate below 600 volts, AC or DC, including, but not limited to, any hardware, control or protective devices, cables, conductors, electric raceways, secondary equipment panels, transducers, batteries, chargers, and voltage and current transformers that directly affect the operation of Developer or Connecting Transmission Owner’s facilities and equipment which may reasonably be expected to impact the other Party. Developer and Connecting Transmission Owner shall each provide advance notice to the other Party, and to NYISO, before undertaking any work on such circuits, especially on electrical circuits involving circuit breaker trip and close contacts, current transformers, or potential transformers.
Developer and Connecting. Transmission Owner agree to report to each other in writing as soon as practical all accidents or occurrences resulting in injuries to SERVICE AGREEMENT NO. 2515 any person, including death, and any property damage arising out of this Agreement. Contractors’ Insurance. Each party will require their Contractors of every level to: procure and maintain the following insurance at its own expense until completion and acceptance of performance hereunder, and thereafter to the extent stated below, with at least the monetary limits specified. The insurance shall be in policy forms which contain an "occurrence" and not a "claims made" determinant of coverage and shall be placed with insurance companies acceptable to the Connecting Transmission Owner.
A. Employment related insurance.
(a) Workers' Compensation Insurance as required by law.
(b) Employer's Liability Insurance, including accidents (with a limit of $1,000,000 per accident) and occupation diseases (with a limit of $1,000,000 per employee).
(c) Where applicable, insurance required by the United States Longshoremen's and harbor Workers' Act, the Federal Employers' Liability Act, and the Xxxxx Act.
B. Commercial General Liability Insurance, including Contractual Liability, with limits of not less than $5,000,000 per occurrence for bodily injury or death and $1,000,000 per occurrence for property damage or a combined single limit of $5,000,000 per occurrence and, for at least one year after completion of performance hereunder, Products/Completed Operations Liability Insurance with similar but separate and independent limits. Every contractor will be responsible for their policies’ deductibles. The insurance shall contain no exclusions for explosion, collapse of a building or structure, or underground hazards. The insurance policy or policies shall name Connecting Transmission Owner and Developer as an additional insured. And their insurance will be primary and non-contributory to any other insurance available to the Additional Insured. There shall be no exclusion for claims by Contractor employees against Connecting Transmission Owner or Developer based on injury to Contractor’s employees.
C. Commercial Automobile Liability Insurance, covering all owned, non- owned and hired automobiles used by the contractor or any subcontractors, with limits of $1,000,000 each accident for bodily injury or death and property damage.
Developer and Connecting. Transmission Owner agree to report to each other in writing as soon as practical all accidents or occurrences resulting in injuries to any person, including death, and any property damage arising out of this Agreement. Contractors’ Insurance. Each party will require their Contractors of every level to: procure and maintain the following insurance at its own expense until completion and acceptance of performance hereunder, and thereafter to the extent stated below, with at least the monetary limits specified. The insurance shall be in policy forms which contain an "occurrence" and not a "claims made" determinant of coverage and shall be placed with insurance companies acceptable to the Connecting Transmission Owner.
A. Employment related insurance.
(a) Workers' Compensation Insurance as required by law.
(b) Employer's Liability Insurance, including accidents (with a limit of $1,000,000 per accident) and occupation diseases (with a limit of $1,000,000 per employee).
(c) Where applicable, insurance required by the United States Longshoremen's and harbor Workers' Act, the Federal Employers' Liability Act, and the Xxxxx Act.
B. Commercial General Liability Insurance, including Contractual Liability, with limits of not less than $5,000,000 per occurrence for bodily injury or death and $1,000,000 per occurrence for property damage or a combined single limit of $5,000,000 per occurrence and, for at least one year after completion of performance hereunder, Products/Completed Operations Liability Insurance with similar but separate and independent limits. Every contractor will be responsible for their policies’ deductibles. The insurance shall contain no exclusions for explosion, collapse of a building or structure, or underground hazards. The insurance policy or policies shall name Connecting Transmission Owner and Developer as an additional insured. And their insurance will be primary and non-contributory to any other insurance available to the Additional Insured. There shall be no exclusion for claims by Contractor employees against Connecting Transmission Owner or Developer based on injury to Contractor’s employees. 42 SERVICE AGREEMENT NO. 2216
C. Commercial Automobile Liability Insurance, covering all owned, non- owned and hired automobiles used by the contractor or any subcontractors, with limits of $1,000,000 each accident for bodily injury or death and property damage.
D. Where the Work involves the use of aircraft, Aircraft Liability Insurance, covering al...
Developer and Connecting. Transmission Owner shall each be responsible for protection of its respective facilities consistent with Good Utility Practice and Applicable Reliability Standards.2
Developer and Connecting. Transmission Owner shall each comply with applicable requirements of NYISO and the New York Public Service Commission when exercising its rights and fulfilling its responsibilities under this Article 7. Unless otherwise agreed by the Connecting Transmission Owner and NYISO approved meter service provider and Developer, the Connecting Transmission Owner shall install Metering Equipment at the Point of Interconnection prior to any operation of the Large Generating Facility and shall own, operate, test and maintain such Metering Equipment. Net power flows including MW and MVAR, MWHR and loss profile data to and from the Large Generating Facility shall be measured at the Point of Interconnection. Connecting Transmission Owner shall provide metering quantities, in analog and/or digital form, as required, to Developer or NYISO upon request. Where the Point of Interconnection for the Large Generating Facility is other than the generator terminal, the Developer shall also provide xxxxx XX and MVAR quantities at the generator terminal. Developer shall bear all reasonable documented costs associated with the purchase, installation, operation, testing and maintenance of the Metering Equipment.
Developer and Connecting. Transmission Owner shall each cooperate with the other in the inspection, maintenance, and testing of control or power circuits that operate below 600 volts, AC or DC, including, but not limited to, any hardware, control or protective devices, cables, conductors, electric raceways, secondary equipment panels, transducers, batteries, chargers, and voltage and current transformers that directly affect the operation of Developer or Connecting Transmission Owner’s facilities and equipment which may reasonably be expected to impact the other Party. Developer and Connecting Transmission Owner shall each provide advance notice to the SERVICE AGREEMENT NO. 2515 other Party, and to NYISO, before undertaking any work on such circuits, especially on electrical circuits involving circuit breaker trip and close contacts, current transformers, or potential transformers.
Developer and Connecting. Transmission Owner shall each, at its own expense, maintain in force throughout the period of this Agreement, and until released by the other Parties, the following minimum insurance coverages, with insurers authorized to do business in the state of New York:
Developer and Connecting. Transmission Owner shall each comply with applicable requirements of NYISO and the New York Public Service Commission when exercising its rights and fulfilling its responsibilities under this Article 7. Unless otherwise agreed by the Connecting Transmission Owner and NYISO approved meter service provider and Developer, the Connecting Transmission Owner shall install Metering Equipment at the Point of Interconnection prior to any operation of the Large Generating Facility and shall own, operate, test and maintain such Metering Equipment. Net power flows including MW and MVAR, MWHR and loss profile data to and from the Large Generating Facility shall be measured at the Point of Interconnection. Connecting Transmission Owner shall provide metering quantities, in analog and/or digital form, as required, to Developer or NYISO upon request. Where the Point of Interconnection for the Large Generating Facility is other than the generator terminal, the Developer shall also provide xxxxx XX and MVAR quantities at the generator terminal. Developer shall bear all reasonable documented costs associated with the purchase, installation, operation, testing and maintenance of the Metering Equipment. Connecting Transmission Owner shall be responsible for the metering at any Metering Points identified by the NYISO in connection with the interconnection of the Transmission Project with Connecting Transmission Owner’s system in accordance with the requirements in this Article 7. Connecting Transmission Owner and/or Transmission Developer shall, as such responsibilities are specified in Appendix A of this Agreement, procure and install any required Metering Equipment prior to any operation of the Transmission Project. Connecting Transmission Owner shall own, operate, test, maintain, and, if directed by the NYISO, relocate such Metering Equipment in accordance with ISO Procedures, as such requirements are amended from time to time. Connecting Transmission Owner shall provide the NYISO with metering data in accordance with the metering requirements set forth in this Agreement, the NYISO Tariffs, and ISO Procedures, as such requirements are amended from time to time. Transmission Developer shall bear all reasonable documented costs associated with the purchase and installation of the Metering Equipment.
Developer and Connecting. Transmission Owner shall each have the right, but shall have no obligation to: (i) observe the other Party’s tests and/or inspection of any of its System Protection Facilities and other protective equipment, including Power System Stabilizers; (ii) review the settings of the other Party’s System Protection Facilities and other protective equipment; and (iii) review the other Party’s maintenance records relative to the Attachment Facilities, the System Protection Facilities and other protective equipment. NYISO shall have these same rights of inspection as to the facilities and equipment of Developer and Connecting Transmission Owner. A Party may exercise these rights from time to time as it deems necessary upon reasonable notice to the other Party. The exercise or non-exercise by a Party of any such rights shall not be construed as an endorsement or confirmation of any element or condition of the Attachment Facilities or the System Protection Facilities or other protective equipment or the operation thereof, or as a warranty as to the fitness, safety, desirability, or reliability of same. Any information that a Party obtains through the exercise of any of its rights under this Article 6.4 shall be treated in accordance with Article 22 of this Agreement and Attachment F to the ISO OATT.