DOORS, FRAMES & HARDWARE Sample Clauses

DOORS, FRAMES & HARDWARE. Landlord shall reuse existing solid core doors and hollow metal frames where applicable. Where required, Landlord shall provide new building standard solid core wood doors with hollow metal frames to match existing. · Landlord shall remove existing entry wood doors and replace with building standard double glass entry door. Door size shall match existing. · Landlord shall provide and install building standard hardware including latch/lock lever sets, binges, door stops where required.
AutoNDA by SimpleDocs
DOORS, FRAMES & HARDWARE. Landlord shall install 3’0” x 7’0” solid core oak doors with clear finish and painted hollow metal frames. Landlord shall provide doors and frames as shown in the attached floor plan. · Landlord shall install Building standard hardware including latch/lock lever sets, hinges, door stops where required.
DOORS, FRAMES & HARDWARE a) Retrofit existing wood doors and frames as per approved Plan #A-1, dated May 5, 2004.
DOORS, FRAMES & HARDWARE. Primary Entrance - One pair fire-rated tempered glass doors, 2@ thick, full height. Frame shall be clear anodized aluminum, and shall extend from the floor to the underside of suspended ceiling. Door hardware shall be clear anodized aluminum. Secondary Egress - 3=-0@ x full height x 1 :@ Red Oak veneer AB@ label wood flush door,. Frame to be 16 ga. Steel hollow metal construction, AB@ label, and shall extend from the floor to the underside of suspended ceiling. Interior Doors - 3=-0@ x 8=-0@ x 1 :@ Hardwood veneer wood flush door suitable for stain finish,. Frame to be 18 ga. Steel hollow metal construction. Hardware - Each Interior door shall be provided with 3 hinges, brushed chrome finish, a passage set, and a door stop. Secondary egress door shall be provided with 4 hinges, brushed chrome finish, a lock set, an overhead door closer, and a door stop. Lock / passage sets shall be ASchlage@ D Series cylindrical sets with AAthens@ lever handles in brushed chrome finish. Acoustical Lay-in Ceilings Acoustical tile - shall be nominal 24@ x 24@ (or 48@) x 5/8@ lay-in;, tegular edged textured ceiling tile, white finish, supported in a white finish 15/16@ grid. Flooring Carpeting and resilient flooring - as per Tenant=s selection. Wall Finish Paint and wallcovering - as per Tenant=s selection. Electrical Receptacles - Spec grade 120v, 20a duplex devices. White finish. Cover plate - stainless steel brushed finish. Wall switches - Spec grade 277v, 20a. toggle . White finish. Cover plate - stainless steel brushed finish. Lighting Air Distribution VAV boxes - Trane Model VCCE. Ceiling Diffusers - Xxxxx Model TDC. Color - #25 Off-White Return Register - Xxxxx Series 23. Color - #25 Off-White Sprinkler Sprinkler heads - chrome plated semi-recessed pendant type, with one piece semi-recessed escutchon.
DOORS, FRAMES & HARDWARE. Tenant Entry: Stile and rail cherry door with custom stain finish and 4” x 30” glass inset. Doors shall be 1 3/4’ x 3’-0” x 8’-0” with integrated glass sidelight. Exit Door: Shall be a solid core wood door with premium select cherry veneer with a custom stain finish. Door shall be 1 3/4” x 3’-0” x 8’ x 0”. Standard Interior Door: Shall be a solid core wood door with premium select cherry veneer with custom stain finish. Door shall be 1 3/4” x 3’-0” x 7’ -- 0”. Entry Door Frame: 1 1/2” hollow metal frame. Exit Door Frame: 1 1/2” hollow metal frame. Entry & Exit Hardware: Entry and exit doors shall be secured by full mortise, lever locksets. These locksets shall be by Schlage Model # L9010, finish 626. The door shall have a surface mounted closer with a matching cover. Ball bearing hinges, floor stops, and silencers will be provided. All exposed metal shall be brushed stainless steel. Use existing where applicable. Interior Door Hardware: Brushed stainless Yale hardware. PARTITIONS Demising Partition: All partitions shall be framed with 2 1/2”, 20 gauge metal studs on 16” centers. The partitions shall be insulated and have two layers of 5/8” thick type “x” gypsum wallboard each side, taped and floated. The partition shall extend from the floor to the deck above and shall be sealed. Typical Partition: All partitions shall be framed with 2 1/2”, 20 gauge metal studs on 16” centers. The partitions shall be insulated and have two layers of 5/8” thick type “x” gypsum wallboard each side, taped and floated. The partition shall extend to 6” above the finished ceiling.
DOORS, FRAMES & HARDWARE a) Seven ( 7 ) xxxxxx xxxx and glass doors 3’ - 0” x 8’ - 0’ with true mullions ( 3 x 7 ) with frosted panes, with 1” clear borders.
DOORS, FRAMES & HARDWARE. Tenant interior doors, frames and hardware shall be consistent with existing construction and as follows:
AutoNDA by SimpleDocs
DOORS, FRAMES & HARDWARE. All doors and frames to remain as is except the existing door from the old break room. This door and frame are removed by abatement contractor. Install new locksets on 3 doors 7. WINDOWS/GLAZING: N/A 8. STOREFRONT SYSTEMS: Install new glass entry door with 180 degree floor closer
DOORS, FRAMES & HARDWARE 

Related to DOORS, FRAMES & HARDWARE

  • Hardware IF HARDWARE IS IDENTIFIED ON A TRANSACTION DOCUMENT, THE SALE AND USE OF THE HARDWARE WILL BE GOVERNED BY TERMS OTHER THAN THIS XXXX. OT DISCLAIMS ALL WARRANTIES AND LIABILITY WITH RESPECT TO THE HARDWARE.

  • Engines POSITION SERIAL NO. TOTAL HOURS TOTAL CYCLES HRS/CYCLES SINCE LAST SHOP VISIT Time Remaining to Next LIFE LIMITED PART REMOVAL PART NAME HOURS CYCLES MSN MSN

  • Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.

  • Hardware and Software Requirements In order to access and retain Disclosures electronically, you must satisfy the following computer hardware and software requirements: access to the Internet; an email account and related software capable of receiving email through the Internet; a web browser which is SSL-compliant and supports secure sessions, and hardware capable of running this software.

  • Company Software “Company Software” shall mean any software (including software development tools and software embedded in hardware devices, and all updates, upgrades, releases, enhancements and bug fixes) owned, developed (or currently being developed), used, marketed, distributed, licensed or sold by an Acquired Corporation at any time (other than non-customized third-party software that is not incorporated into any Company Product and is licensed to an Acquired Corporation solely in object code form and solely for internal use on a non-exclusive basis).

  • Tooling Unless otherwise specified in this Agreement, all tooling and/or all other articles required for the performance hereof shall be furnished by Seller, maintained in good condition and replaced when necessary at Seller's expense. If NETAPP agrees to pay Seller for special tooling or other items either separately or as a stated part of the unit price of Goods purchased herein, title to same shall be and remain in NETAPP upon payment therefore.

  • Doors Exterior doors may not be propped open for safety and security reasons. Students may be referred to the student conduct system if found propping these doors. Doors marked as emergency exits may only be used for emergency purposes other than during University-sanctioned move-in days.

  • Spares Boeing will revise, as applicable, the customized Recommended Spares Parts List (RSPL) and Illustrated Parts Catalog (IPC).

  • Airframe The Airbus A300F4-605R aircraft (excluding the Engines or engines from time to time installed thereon) to be leased by the Lessor to the Lessee pursuant to the Lease and the initial Lease Supplement and having the United States FAA Registration Number initially and manufacturer's serial number specified in the initial Lease Supplement, including (i) all Parts in respect thereof and (ii) any Replacement Airframe which may be substituted pursuant to Section 11.03

  • Equipment, Etc Each Grantor shall, (i) within ten (10) days after a written request by the Administrative Agent, in the case of Equipment now owned, and (ii) following a request by the Administrative Agent pursuant to subclause (i) above, within ten (10) days after acquiring any other Equipment, deliver to the Administrative Agent, any and all certificates of title, and applications therefor, if any, of such Equipment and shall cause the Administrative Agent to be named as lienholder on any such certificate of title and applications. No Grantor shall permit any such items to become a fixture to real estate or an accession to other personal property unless such real estate or personal property is the subject of a fixture filing (as defined in the UCC) creating a first priority perfected Lien in favor of the Administrative Agent.