Emergency Stop Sample Clauses

Emergency Stop. The system is provided with a hardware input that can be used to prevent operation of the traction system and isolate the HVDC contactors that connect the drive system to the vehicle batteries.
AutoNDA by SimpleDocs
Emergency Stop. Depress the emergency stop button to verify that the alarm sounds. If the unit is also equipped with an emergency stop, make sure the alarm continues to sound when the stop button is depressed.
Emergency Stop. Independent, guarded, manually actuated emergency shutdown switches shall be provided at each control station. One (1) emergency stop switch shall be provided for each propulsion train, and the switch shall stop both engines connected to that propulsion train. 256 MACHINERY COOLING SYSTEMS Install fresh water and seawater cooling systems to provide machinery-cooling systems, generally as shown on References (2C) and (2D). Arrange major system components generally where shown on Reference (2A). Cooling systems and equipment shall meet the requirements of the engine manufacturer, gear manufacturer, VSP or approved equal manufacturer, and Regulatory Bodies, in addition to the requirements listed below and the general requirements of Group 500. Machinery cooling systems shall be complete in all respects with all necessary pumps, gauges, controls, strainers, piping, valves, fittings, orifices, indicators, etc., required for efficient operation.
Emergency Stop allows setting stop trading parameter when some situations appear. To enable this property you should check “Use emergency stop”. • Stop copying if Equity level is less than … (in base currency of your account) – when this option is enabled Copier will stop receiving signals from Source terminal in case when Equity level of Receiver account is less than value in Stop copying if Equity level is less than. To enable this option you should check it. • Stop copying if Drawdown Percent is bigger than … – when this option is enabled Xxxxxx will stop receiving "Open order" signals from Source terminal in case when Drawdown percent of Receiver account is better than some value. Drawdown is calculated as the difference between current Equity and maximum historical Equity in percentage. To enable this option you should check it. • Stop copying if Drawdown Value is bigger than … (in base currency of your account) – when this option is enabled Copier will stop receiving "Open order" signals from Source terminal in case when Drawdown value of Receiver account is better than some value. To enable this option you should check it. Close all orders if one of above conditions met – if this setting is checked, all orders will be immediately closed if one of conditions happens.
Emergency Stop. In case of danger, switching-off of the 4 main motors of the calender is effected by easily accessible red-white marked ropes or bars via emergency switches as well as mushroom-type stop buttons in the control panel. In case of an emergency stop of the line, stand-still of the calender is effected by electrical braking of the 4 drive motors. In accordance with local requirements, the calender rolls will be stopped within a roll surface travel (m) of 0.0175 x surface speed (m/min) of the fastest calender roll. At the same time, the calender nip is opened by moving off the calender rolls until limit switches are contacted. In case of an emergency stop an acoustic signal is given.
Emergency Stop. To switch off the drive motors in case of emergency, safety equipment shall be provided at points of the post calender equipment to be defined later. In case of emergency stop, an acoustic signal is given. The roller drives of the post calender equipment are stopped immediately by means of electrical braking and at the same time all rollers of the take-off unit, tempering and cooling unit open up to the limit switches. The control panel shall be provided with indicators to show which of the switches has become operative.
Emergency Stop device that causes a controlled stop as quickly and as safely as possible and which overrides all other controls
AutoNDA by SimpleDocs
Emergency Stop. Machinery installations shall have an emergency stop function which stops the drive system. The emergency stop system may either implement a Category 0, or a Category 1 stop for the equipment. The choice of category shall be on the basis of a risk assessment and the functional needs of the machine. Category 0: Stopping by immediate removal of power to the drive elements of the machine (uncontrolled stop); Category 1: A controlled stop with power available to the drive elements of the machine to achieve the stop and then a guaranteed removal of power.
Emergency Stop. The contractor shall provide an emergency stop system in accordance with ISO 13850
Emergency Stop. To avoid collision, it can be necessary to carry out an emergency stop. For the most efficient stop you have to reduce the engine speed to approx. 50% and then move lever to zero position and then slowly further to astern. This will avoid cavitation and low efficiency and the propeller in the astern position. Only training and experience will give a necessary knowledge of the best stopping procedure for your vessel. We will recommend this to be a part of the training procedure for the officers. Please compare this procedure to what the engine manufacturer recommends. This to prevent a situation either where the engine will overload, or worse; choking the engine.