Lighting and Power Sample Clauses

Lighting and Power. The Contractor shall provide all artificial lighting and power for use on the works, including all temporary supply and connections, wiring, fittings, etc., and clear away on completion. The Contractor shall pay all fees and obtain all permits in connection therewith. For lighting and power for Nominated Sub-Contractors and Specialist, see Item … Water The Contractor shall provide at his own risk and cost all water for use in connection with the works, make arrangements with the Local Authority for the installation of a separate meter for all water used by him throughout the contract and pay all costs and fees in connection therewith. He shall also provide temporary storage tanks and tubing, etc, as he may consider necessary and clear away at completion. All water shall be fresh, clean and pure, free from earthly, vegetable or organic matter, acid or alkaline substance in solution or suspension. Carried to Collection Item Description QTY UNIT RATE AMOUNT B C D Existing Services Prior to commencement of any works the Contractor is to ascertain from the relevant authorities the exact position, depth and level of existing electric cables, water pipes or other services in the area and he shall make whatever provisions may be required by the authorities concerned for the support and protection of such services. Any damage or disturbance caused to any service shall be reported immediately to the Architect and the relevant authority and shall be made good to their satisfaction at the Contractor’s expense. The Contractor must make himself fully acquainted with current Acts and Regulations, including Police Regulations regarding all such regulations and/or restrictions which may affect the organization of the works, supply and control of labour, etc., and allow accordingly in his tender. No claim in respect of want of knowledge in this connection will be entertained. Particular attention is drawn to the Rules published in Legal Notice 179, dated 2nd June ,1978
AutoNDA by SimpleDocs
Lighting and Power. 21.1 The Employer shall make no charge to the Contractor for the electricity consumed for carrying out and completing the Works. However, the Employer reserves the right to require the Contractor to arrange for his own temporary electricity meter with the power company at his own cost if in the opinion of the Employer the demand is large or likely to cause an overload to the Employer’s distribution system.
Lighting and Power. Main electrical distribution board is behind the stage; electrical circuit breakers may need to be reset if the heating is incorrectly operated. The heating controls are located on 3 banks of switches in bays on left hand side of hall with instructions in the first bay. The light switch next to entrance door operates lights in entrance hall and outside. Light switches immediately on the right as you enter the hall operate the two lights in the first bay; other light switches are behind door leading to stage. Kitchen and annexe have switches just inside the area. Various power sockets are located around the hall. If you bring your own electrical appliances, they must meet safety standards. WATER The main stopcock is located under worktop to the left of the kitchen sink ACCESS RAMP TO GARDENS Located by double doors to garden adjacent to kitchen. CAR PARKING The hall car park will accommodate 12 cars if they are parked sensibly. There are two allocated disabled parking spaces at the front of the hall adjacent to access ramp. All cars parked at owner’s risk. Please ask your guests to leave quietly at the close of your event. Car doors banging and loud talk in the car park are disturbing to local residents.
Lighting and Power. The Contractor shall provide all artificial lighting and power for use on the works, including all temporary supply and connections, wiring, fittings, etc., and clear away on completion. The Water The Contractor shall provide at his own risk and cost all water for use in connection with the works, make arrangements with the Local Authority for the installation of a separate meter for all water used by him throughout the contract and pay all costs and fees in connection therewith. He shall also provide temporary storage tanks and tubing, etc, as he may consider necessary and clear away at completion. All water shall be fresh, clean and pure, free from earthly, vegetable or organic matter, acid or alkaline substance in solution or suspension. TOTAL CARRIED TO COLLECTION Item Description QTY UNIT RATE AMOUNT B C D Existing Services Prior to commencement of any works the Contractor is to ascertain from the relevant authorities the exact position, depth and level of existing electric cables, water pipes or other services in the area and he shall make whatever provisions may be required by the authorities concerned for the support and protection of such services. Any damage or disturbance caused to any service shall be reported immediately to the Architect and the relevant authority and shall be made good to their satisfaction at the Contractor’s expense. The Contractor must make himself fully acquainted with current Acts and Regulations, including Police Regulations regarding all such regulations and/or restrictions which may affect the organization of the works, supply and control of labour, etc., and allow accordingly in his tender. No claim in respect of want of knowledge in this connection will be entertained. Particular attention is drawn to the Rules published in Legal Notice 179, dated 2nd
Lighting and Power. Main electrical distribution board is behind the stage; electrical circuit breakers may need to be reset if the heating is incorrectly operated. A second fusebox (operating the lights in the entrance hall and lavatories) is in the storage cupboard on the right as you walk in to the main hall. The heating controls are located on banks of switches in bays on left hand side of hall. Press the timer switches once to obtain15 mins heat, twice for 30 mins, 3 x for 1 hour or 4 x for 2 hours heating. Pressing the timer button once again after the 2 hour selection will clear the timer and turn off the heating. Please turn off the heating when you leave. The light switch next to entrance door operates lights in entrance hall and outside. Light switches in the main hall will operate the tube lighting (bright lighting) OR the spotlights, which can be dimmed to create softer lighting. Kitchen and annexe have switches just inside the area. Various power sockets are located around the hall. If you bring your own electrical appliances, they must meet safety standards. WATER The main stopcock is located under worktop to the left of the kitchen sink ACCESS RAMP TO GARDENS Located by double doors to garden adjacent to kitchen. CAR PARKING The hall car park will accommodate 12 cars if they are parked sensibly. There are two allocated disabled parking spaces at the front of the hall adjacent to access ramp. All cars parked at owner’s risk. Please ask your guests to leave quietly at the close of your event. Car doors banging and loud talk in the car park are disturbing to local residents.
Lighting and Power. 17 1. Wires, Cables and Conduit........................................ 17 2.
Lighting and Power. The Contractor shall provide at his own risk and cost all artificial lighting and power for use on the Works, including all Sub-Contractors' and Specialists' requirements and including all temporary connections, wiring, fittings, etc., and clearing away on completion. The Contractor shall pay all fees and obtain all permits in connection therewith.
AutoNDA by SimpleDocs
Lighting and Power. The Tenant is responsible for providing and installing all lighting and power equipment necessary to complete the electrical system for its Tenant Improvement space. It's system shall be integrated with the Base Building energy management system.
Lighting and Power. There are power supplies inside the building Office. Make temporary connections and disconnections and provide all necessary distribution around the site and allow for any additional power requirements and for all associated costs.

Related to Lighting and Power

  • Existence and Power The Seller is a limited liability company validly existing and in good standing under the laws of the State of Delaware and has, in all material respects, all power and authority required to carry on its business as it is now conducted. The Seller has obtained all necessary licenses and approvals in each jurisdiction where the failure to do so would materially and adversely affect the ability of the Seller to perform its obligations under the Transaction Documents or affect the enforceability or collectibility of the Receivables or any other part of the Transferred Assets.

  • Authorization and Power Such Subscriber has the requisite power and authority to enter into and perform this Agreement and the other Transaction Documents (as defined herein) and to purchase the Note and Warrants being sold to it hereunder. The execution, delivery and performance of this Agreement and the other Transaction Documents by such Subscriber and the consummation by it of the transactions contemplated hereby and thereby have been duly authorized by all necessary corporate action, and no further consent or authorization of Subscriber or its board of directors or stockholders, if applicable, is required. This Agreement and the other Transaction Documents have been duly authorized, executed and delivered by such Subscriber and constitutes, or shall constitute, when executed and delivered, a valid and binding obligation of such Subscriber, enforceable against Subscriber in accordance with the terms thereof.

  • Organization and Power The Purchaser is duly organized, validly existing, and in good standing under the laws of the jurisdiction of its formation and has all requisite power and authority to carry on its business as presently conducted and as proposed to be conducted.

  • Organization, Standing and Power Each of the Company and each of the Company’s Subsidiaries (the “Company Subsidiaries”) is duly organized, validly existing and in good standing under the Laws of the jurisdiction in which it is organized (in the case of good standing, to the extent such jurisdiction recognizes such concept), except, in the case of the Company Subsidiaries, where the failure to be so organized, existing or in good standing, individually or in the aggregate, has not had and would not reasonably be expected to have a Company Material Adverse Effect. Each of the Company and the Company Subsidiaries has all requisite corporate or similar power and authority and possesses all Permits necessary to enable it to own, lease, operate or otherwise hold its properties and assets and to conduct its businesses as presently conducted (the “Company Permits”), except where the failure to have such power or authority or to possess the Company Permits, individually or in the aggregate, has not had and would not reasonably be expected to have a Company Material Adverse Effect. Each of the Company and the Company Subsidiaries is duly qualified or licensed to do business in each jurisdiction where the nature of its business or the ownership, operation or leasing of its properties and assets makes such qualification necessary, other than in such jurisdictions where the failure to be so qualified or licensed, individually or in the aggregate, has not had and would not reasonably be expected to have a Company Material Adverse Effect. The Company has made available to Parent, prior to execution of this Agreement, true and complete copies of the Amended and Restated Articles of Incorporation of the Company in effect as of the date of this Agreement, together with all amendments thereto in effect as of the date of this Agreement (the “Company Articles”), and the Amended and Restated Regulations of the Company in effect as of the date of this Agreement, together with all amendments thereto in effect as of the date of this Agreement (the “Company Regulations”). Each of the Company Articles and the Company Regulations were duly adopted and is in full force and effect as of the date of this Agreement. Neither the Company nor any Company Subsidiary is in violation in any material respect of any provision of such documents.

  • Organization and Powers Each Loan Party is a corporation duly organized, validly existing and in good standing under the laws of its jurisdiction of incorporation as specified in Schedule 5.1 annexed hereto. Each Loan Party has all requisite corporate power and authority to own and operate its properties, to carry on its business as now conducted and as proposed to be conducted, to enter into the Loan Documents and Related Agreements to which it is a party and to carry out the transactions contemplated thereby.

  • Organization, Good Standing and Power The Company is a corporation duly organized, validly existing and in good standing under the laws of the State of Delaware and has the requisite corporate power and authority to own, lease and operate its properties and assets and to conduct its business as it is now being conducted. The Company and each Subsidiary is duly qualified as a foreign corporation to do business and is in good standing in every jurisdiction in which the nature of the business conducted or property owned by it makes such qualification necessary, except for any jurisdiction in which the failure to be so qualified would not have a Material Adverse Effect.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!