Measurement of Quantity Sample Clauses

Measurement of Quantity. ~The State may measure the quantity of work performed and these measurements shall be final and binding. All work computed under contract shall be measured according to United States Measurements and Weights. Method of measurements is specified in the Special Conditions.
AutoNDA by SimpleDocs
Measurement of Quantity. The volume will be calculated as Net Standard Volume (NSV) and it shall be construed as the total volume of all the petroleum liquids, excluding sediment and water (BSW) art a standard temperature of 60º F. The measurement can be made with static or dynamic measurement, applying the methods described in the MMH.
Measurement of Quantity. (A) Quantities of LSFO and Line Displacement Stock shipped between the facilities by pipeline including quantities of same Delivered by Pipeline Delivery hereunder shall be determined at the time of the Pipeline Delivery by gauging Chevron’s tanks before and after pumping under the supervision of the Independent Inspector. Quantities of LSFO and Line Displacement Stock pumped, sold or Delivered by Chevron and purchased or received by HECO hereunder shall be calculated in accordance with the current measurement standards adopted by industry, ASTM, API and other recognized standard-setting bodies as are applicable in the opinion of the Independent Inspector and shall be expressed in G.S.V., U.S. barrels at 60 degrees Fahrenheit.
Measurement of Quantity. The quantity of Biodiesel sold and purchased under this Contract shall be determined at the time of the discharging of each Transport Container or tanker truck by HECO’s automated discharge rack control system at HECO’s CIP Facility which shall employ calibrated meters, corrected in each instance to measure volume in U.S. gallons consisting of two hundred thirty-one (231) cubic inches when corrected to 60 degrees Farenheit. All gauging, sampling and testing of the Biodiesel shall be performed in accordance with the latest methods of the American Petroleum Institute’s Manual of Petroleum Measurement Standards (API MPMS) and the American Society for Testing and Materials (ASTM). All quantity determinations shall be made in accordance with then currently applicable ASTM methodology. The actual quantity received and delivered shall be the measured quantity reported in Gallons at 60 degrees Fahrenheit. However, it is recognized that volume correction factors and other measurement standards for bulk Biodiesel movements have yet to be fully developed or universally adopted. The parties agree to mutually consider and implement such standards when and as applicable. HECO shall perform normal maintenance procedures to maintain the accuracy of the meters used to measure the quantity of Biodiesel discharged from Transport Container(s) or tanker truck(s) for delivery to HECO. HECO, also at its own expense, shall test for accuracy and calibrate the meters on a semi-annual basis or as required and agreed by the Parties. HECO shall provide Seller with a written schedule of calibration test times and Seller shall have the right to have its representative present to observe each calibration test.
Measurement of Quantity. (a) The parties agree to use the best practical method for measuring Sewage delivered to the WWTP by City, as follows:
Measurement of Quantity. Volume will be settled as Net Standard Volume (NSV) and shall be understood to be the total volume of all petroleum liquids, excluding sediment and water (BSW) at a standard temperature of 60° F. The metering can be performed with dynamic or static metering, using the methods described in the MMH. The volume, over which the crude delivered by SELLER at the input flange at the Tumaco Plant will be the volume that results from application of the volumetric compensation and sent by CENIT TRANSPORTE Y
Measurement of Quantity. The quantity of Biodiesel sold and purchased under this Contract shall be determined at the time of the discharging of each Transport Container or tanker truck by Hawaiian Electric’s automated discharge rack control system at Hawaiian Electric’s CIP Facility and/or HIA EPF which shall employ calibrated meters, corrected in each instance to measure volume in U.S. gallons consisting of two hundred thirty-one (231) cubic inches when corrected to sixty degrees Xxxxxxxxxx (00° F). All gauging, sampling and testing of the Biodiesel shall be performed in accordance with the latest methods of the American Petroleum Institute’s Manual of Petroleum Measurement Standards (API MPMS) and the American Society for Testing and Materials (ASTM). All quantity determinations shall be made in accordance with then currently applicable ASTM methodology. The actual quantity received and Delivered shall be the measured quantity reported in Gallons at 60 degrees Xxxxxxxxxx (00° F). However, it is recognized that volume correction factors and other measurement standards for bulk Biodiesel movements have yet to be fully developed or universally adopted. The Parties agree to mutually consider and implement such standards when and as applicable. Hawaiian Electric shall perform normal maintenance procedures to maintain the accuracy of the meters used to measure the quantity of Biodiesel discharged from Transport Container(s) or tanker truck(s) for Delivery to Hawaiian Electric. Hawaiian Electric, also at its own expense, shall test for accuracy and calibrate the meters on a semi-annual basis or as required and agreed by the Parties. Hawaiian Electric shall provide Seller with a written schedule of calibration test times and Seller shall have the right to have its representative present to observe each calibration test.
AutoNDA by SimpleDocs
Measurement of Quantity. The quantity of the Biofuel sold and purchased under this Contract shall be determined at the time of such shipment by gauging the receiving tank(s) immediately before and after pumping under the supervision of the Independent Inspector. Seller and Hawaiian Electric shall share equally the cost of independent inspections. The quantity of Biofuel received by Hawaiian Electric from Seller shall be measured in U.S. gallon consists of two hundred thirty-one (231) cubic inches when corrected to 60 degrees Fahrenheit. All gauging, sampling and testing of the Biofuel shall be performed in accordance with the latest methods of the American Petroleum Institute’s Manual Of Petroleum measurement Standards (API MPMS) and the American Society for Testing and Materials (ASTM). All quantity determinations shall be made in accordance with then currently applicable ASTM methodology. The actual quantity received and Delivered shall be the measured quantity reported in Gallons at 60 degrees Fahrenheit. However, it is recognized that volume correction factors and other measurement standards for bulk Biofuel movements have yet to be fully developed or universally adopted. The Parties agree to mutually consider and implement such standards when and as applicable. The Independent Inspector shall prepare and sign a Certificate of Quantity stating the quantity of Biofuel determined according to the provisions of this Section to have been Delivered to Hawaiian Electric and received by Hawaiian Electric or its nominated third-party Receiving Facility; it shall furnish Seller and Hawaiian Electric each with a copy of such Certificate; and advise by facsimile or electronic mail the quantity of Biofuel Delivered to Hawaiian Electric and received by Hawaiian Electric or the third party Receiving Facility to Seller and Hawaiian Electric. The data in the Independent Inspector’s Certificate of Quantity prepared as provided herein shall, absent fraud or errors and omissions, be binding and conclusive upon both Parties, and shall be used for verification of the Biofuel sales invoice.
Measurement of Quantity. Wastewater Treatment ---------------------------------------------- The quantity of Wastewater entering the Wastewater Treatment plant from the Manufacturing Facility is measured with mass flow meters. This will give real time Wastewater flow and 24-hour totalization that will be recorded on a daily basis for accounting purposes. The quantity of Wastewater being discharged from the Wastewater Treatment plant is measured with mass flow meters. This will give real time Wastewater flow and 24-hour totalization that will be recorded on a daily basis for accounting purposes. UTILITIES REQUIREMENTS BASELINE: ------------------------------- Steam * Compressed Air * Wastewater * Hot Water * Signed and acknowledged this 4th day of September, 2001 XXXXXXXXX-AMERICAS-I, L.L.C. * COMPANY, L.P. Individually and on behalf of its Affiliate/Division, * North America By: By: * ----------------------------- ------------------------------------- Name: Xxxxxx Xxxxxxxxx, Manager Name/Title: * ------------------------------ ----------------------------------- * Confidential treatment requested. Confidential Treatment Schedule 5.1 Operation and Maintenance Obligation ------------------------------------ Responsibilities of Xxxxxxxxx-Americas DEFINITIONS;
Measurement of Quantity. The quantity of marine fuel delivered shall be measured by the barge effecting delivery or by gauging in the supplier's store tank or oil meter, in accordance with the ASTM-IP Petroleum Measurement Tables, or the methods of any other recognised standards authority at the discretion of the Seller or its supplier.
Time is Money Join Law Insider Premium to draft better contracts faster.