Outline Specification Sample Clauses

Outline Specification. The Consultant shall prepare an outline specification in Construction Specification Institute format which will describe the Consultant requirements, earthwork, utility adjustments and relocations, substructure restoration, superstructure restoration, drainage, foundations restoration, mechanical, electrical, utilities, lighting, signalization, signage, markings, external finishes, interior historic finishes restoration, painting, security systems, fire protection systems, plumbing, and other incidental and special equipment being proposed for the Project, all of which will be considerations in the cost estimate.
AutoNDA by SimpleDocs
Outline Specification. ANNEXURE 6..............................................................
Outline Specification. Design Conditions Heating and air conditioning systems will be capable of maintaining inside temperatures of 72 degrees Fahrenheit at -10 degrees Fahrenheit outside winter conditions and 72 degrees Fahrenheit dry bulb inside at 92 degrees Fahrenheit dry bulb and 75 degrees Fahrenheit wet bulb outside summer conditions. Loading area and mechanical/electrical room areas will be heated to 60 degrees Fahrenheit at -10 degrees Fahrenheit winter conditions. Ventilation air from the· outside will be provided at a minimum of 20 CFM per person for up to 1050 people (21,000 cfm) or in sufficient quantity to make-up all required exhaust, whichever is greater. Humidification is not included within the scope of this specification. For load calculations, the average occupancy has been based on 142 usable square feet per person and 5.0 xxxxx per square foot for lighting, equipment and miscellaneous loads over 150,000 assumed usable square feet. Air-Conditioning & Heating System Description The following HVAC system is included: VAV Packaged Rooftop System The air conditioning system will utilize weather proof, insulated, roof mounted, packaged, variable air volume cooling and ventilating units. The units will have a direct expansion cooling coil; air cooled condensing unit with capacity control; two (2) sets of throw-away filters; and an enthalpy economizer cycle, with exhaust fan, permitting the use of outside air for cooling at favorable outside dry bulb temperature and relative humidity. Rooftop units will be screened as necessary to meet Code. The rooftop units will be equal to XxXxxx or Trane. The system air volume will vary in response to a system static pressure controller. Computer rooms, or any other room requiring dedicated HVAC systems, will be provided as part of the tenant improvement allowance. The base building HVAC cooling system may be used to supplement and/or back- up the special area systems. The base building cooling load is based on approx. one (1) ton per 320 rentable square feet (excluding lower level) for a total of 500 tons. The Base Building HVAC system will consist of rooftop VAV units, main supply ductwork, return plenum, six (6) fan powered VAV boxes with electric heat on the 2nd and 4th floors, four (4) tan powered VAV boxes with electric heat on the 3rd floor and (1) one fan powered VAV box with electric heat on the 1st floor. Each of the fan powered YAV boxes provide temporary heat and are equipped with localized thermostats. The Base Bui...
Outline Specification. Security System Security system is included within the Base Building scope of work to provide for Base Building entry door card readers, garage entry card reader, fire monitoring, elevator monitoring, elevator traveling cable security capability and other security items as required for the base building plus expansion capability for tenant security needs. Fire Alarm System Fire Alarm System - A complete UL approved fire management system consisting of a fire command station, pull alarm detection system, xxxx alarms, strobe lighting and a fire department telephone communication system will be provided as part of the Base Building scope for the common areas. The system will monitor sprinkler flow, isolating valves, smoke detectors, and individual pull alarms.
Outline Specification. The Outline Specification is contained on the CD attached and the documents detailed in this schedule

Related to Outline Specification

  • The Specifications The Specifications are that portion of the Contract Documents consisting of the written requirements for materials, equipment, systems, standards and workmanship for the Work, and performance of related services.

  • DAF Specifications Developer shall submit initial specifications for the DAF, including System Protection Facilities, to Connecting Transmission Owner and NYISO at least one hundred eighty (180) Calendar Days prior to the Initial Synchronization Date; and final specifications for review and comment at least ninety (90) Calendar Days prior to the Initial Synchronization Date. Connecting Transmission Owner and NYISO shall review such specifications to ensure that the DAF are compatible with the technical specifications, operational control, and safety requirements of the Connecting Transmission Owner and NYISO and comment on such specifications within thirty (30) Calendar Days of Developer’s submission. All specifications provided hereunder shall be deemed to be Confidential Information.

  • Technical Specifications The Technical Specifications furnished on the CD are intended to establish the standards for quality, performance and technical requirements for all labor, workmanship, material, methods and equipment necessary to complete the Work. When specifications and drawings are provided or referenced by the County, these are to be considered part of the Scope of Work, and to be specifically documented in the Detailed Scope of Work. For convenience, the County supplied specifications, if any, and the Technical Specifications furnished on the CD.

  • Service Specification The Parties have agreed upon the scope and specification of the Services provided under this Service Agreement in the Service Specification.

  • Escrow Format Specification Deposit’s Format. Registry objects, such as domains, contacts, name servers, registrars, etc. will be compiled into a file constructed as described in draft-xxxxx-xxxxxxx-registry-data-escrow, see Part A, Section 9, reference 1 of this Specification and draft-xxxxx-xxxxxxx-dnrd-objects-mapping, see Part A, Section 9, reference 2 of this Specification (collectively, the “DNDE Specification”). The DNDE Specification describes some elements as optional; Registry Operator will include those elements in the Deposits if they are available. If not already an RFC, Registry Operator will use the most recent draft version of the DNDE Specification available at the Effective Date. Registry Operator may at its election use newer versions of the DNDE Specification after the Effective Date. Once the DNDE Specification is published as an RFC, Registry Operator will implement that version of the DNDE Specification, no later than one hundred eighty (180) calendar days after. UTF-8 character encoding will be used.

  • Equipment Specifications All equipment must meet the contract specifications and all federal and State safety codes and regulations in effect at the date of manufacture. All equipment must be Original Equipment Manufacturer (OEM) equipment unless otherwise stated in the contract. All products, materials, supplies, replacement parts, and equipment offered and furnished must be new, of current manufacturer production, and must have been formally announced by the manufacturer as being commercially available, unless otherwise stated in this Contract.

  • Quality Specifications SANMINA-SCI shall comply with the quality specifications set forth in its Quality Manual, incorporated by reference herein, a copy of which is available from SANMINA-SCI upon request.

  • General specifications For the purpose of this Regulation, the vehicle shall fulfil the following requirements:

  • Packing Specifications 7.3.1 A pack will contain a minimum of one message record or a maximum of 99,999 message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of 99 packs and a minimum of one pack.

  • ODUF Packing Specifications 6.3.1 A pack will contain a minimum of one message record or a maximum of 99,999 message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of 99 packs and a minimum of one pack.