Maintenance and Calibration Sample Clauses

Maintenance and Calibration. (a) All in situ monitoring instruments would be calibrated and calibrated by ALS Technichem (HK) Pty Ltd. before use and at 3-monthly intervals throughout all stages of the water quality monitoring programme. Calibration details are provided in Appendix E. (b) The dissolved oxygen probe of YSI 6820 was calibrated by wet bulb method. Before the calibration routine, the sensor for dissolved oxygen was thermally equilibrated in water- saturated air. Calibration cup is served as a calibration chamber and it was loosened from airtight condition before it is used for the calibration. Calibration at ALS Technichem (HK) Pty Ltd. was carried out once every three months in a water sample with a known concentration of dissolved oxygen. The sensor was immersed in the water and after thermal equilibration, the known mg/L value was keyed in and the calibration was carried out automatically. (c) The turbidity probe of YSI 6820 is calibrated two times a month. A zero check in distilled water was performed with the turbidity probe of YSI 6820 once per monitoring day. The probe will be calibrated with a solution of known NTU at ALS Technichem (HK) Pty Ltd. once every three months.
AutoNDA by SimpleDocs
Maintenance and Calibration. (a) The microphone head of the sound level meter was cleaned with soft cloth at regular intervals. (b) The meter and calibrator were sent to the supplier or HOKLAS laboratory to check and calibrate at yearly intervals. (c) Calibration certificates of the sound level meters and acoustic calibrators are provided in Appendix E.
Maintenance and Calibration. (i) The 1-hour TSP meter was calibrated at 1-year intervals against a continuous particulate TEOM Monitor, Series 1400ab. Calibration certificates of the Laser Dust Monitors are provided in Appendix E. (ii) 1-hour validation checking of the TSP meter against HVS is carried out on half-year basis at the air quality monitoring locations.
Maintenance and Calibration. (i) The HVS and its accessories were maintained in good working condition, such as replacing motor brushes routinely and checking electrical wiring to ensure a continuous power supply. (ii) 5-point calibration of the HVS was conducted using TE-5025A Calibration Kit prior to the commencement of baseline monitoring. Bi-monthly 5-point calibration of the HVS will be carried out during impact monitoring. (iii) Calibration certificate of the HVSs are provided in Appendix E. 2.5.2 1- hour TSP Monitoring (a) Measuring Procedures The measuring procedures of the 1-hour dust meter were in accordance with the Manufacturer’s Instruction Manual as follows:- (i) Turn the power on. (ii) Close the air collecting opening cover. (iii) Push the “TIME SETTING” switch to [BG]. (iv) Push “START/STOP” switch to perform background measurement for 6 seconds. (v) Turn the knob at SENSI ADJ position to insert the light scattering plate. (vi) Leave the equipment for 1 minute upon “SPAN CHECK” is indicated in the display. (vii) Push “START/STOP” switch to perform automatic sensitivity adjustment. This measurement takes 1 minute. (viii) Pull out the knob and return it to MEASURE position. (ix) Push the “TIME SETTING” switch the time set in the display to 3 hours. (x) Lower down the air collection opening cover. (xi) Push “START/STOP” switch to start measurement.
Maintenance and Calibration. The Lessee shall keep and maintain the Equipment during the term of this Agreement at his own cost and expense. The Lessee shall keep the equipment in good state of repair, however normal wear and tear are accepted. Maintenance and use of the Equipment must be carried out in accordance with the instructions set out in Schedule 2. The Lessee shall not change, alter or modify (or obtain the service of any other party to change, alter or modify) the Equipment in any way without LOGSTOR´s prior written approval. Repairs to the Equipment may only be performed by LOGSTOR or by a third party approved by LOGSTOR. The Equipment may only be used and operated in a careful and proper manner and always in accordance with all laws, regulations and any other requirements. The Lessee is not entitled to sublease the Equipment, or make the Equipment available to any third party other than as explicitly agreed by LOGSTOR. §9. Vedligeholdelse og kalibrering Leasingtager skal for egen regning holde og vedligeholde Udstyret i aftaleperioden/leasingperioden. Leasingtager skal holde Udstyret i god vedligeholdelsesmæssig stand bortset fra almindelig slid og ælde. Vedligeholdelse og brug af Udstyret skal ske i overensstemmelse med de i Bilag 2 anførte anvisninger. Leasingtager må ikke på nogen måde ændre eller modificere (eller foranledige at en anden part ændrer eller modificerer) Udstyret uden LOGSTORs forudgående skriftlige samtykke. Reparationer på Udstyret må kun foretages af LOGSTOR eller af en af LOGSTOR godkendt tredjemand. Udstyret må kun anvendes og betjenes på en omhyggelig og korrekt måde og altid i overensstemmelse med alle love, regler og krav. Leasingtager er ikke berettiget til at fremleje Udstyret eller stille Udstyret til rådighed for tredjemand, medmindre det er udtrykkeligt aftalt med LOGSTOR.
Maintenance and Calibration. 3.3.1 FRESENIUS KABI will complete all equipment and instrument maintenance and calibration. X
Maintenance and Calibration. 3.3.1 Baxter will complete all equipment and instrument maintenance and calibration. X
AutoNDA by SimpleDocs
Maintenance and Calibration. CM assures all tooling and equipment used in the manufacture and test of MFR Product shall be maintained fit for production at all times in good working order and under calibration control if it is determined necessary by both parties.
Maintenance and Calibration. Flextronics will put in place a system to ensure that Agilent Property consisting of test equipment provided to Flextronics is calibrated before use. Calibration will be done annually, or as required, and be done to industry acceptable standards (CGMP Standards) or as otherwise specified by Agilent. Flextronics will be held liable for any repair and replacement costs, normal wear and tear excepted, if damage to such test equipment is solely caused by Flextronics. Maintenance and calibration costs, and other related direct costs of other Agilent Property are to be mutually agreed to by Agilent and Flextronics.
Maintenance and Calibration. Periodic maintenance/calibration and documentation will be performed on all instruments and equipment in accordance with manufacturer’s specifications and the latest standards given in the California Code of Regulations, National Fire Protection Association, Fed. OSHA, and Title 22. The frequency of PM (Periodic Maintenance) inspections is stated on the attached inventory list. Periodic maintenance and/or repair of all equipment will be completed on site whenever possible. Any piece of equipment which Contractor repairs that requires calibration as part of its normal use will be re-calibrated after said repair. Any piece of equipment in this category found not re-calibrated after a requested repair will be referred back to Contractor for such calibration and there will be no charge for the additional time needed to effect calibration under these circumstances.