Wastewater Treatment Plant Improvements. Provide a thorough analysis of increasing the capacity of the Albany County Sewer District (ACSD) and Rensselaer County Sewer District (RCSD) Wastewater Treatment Plants to handle higher peak wet weather flows because this is one way to reduce the frequency and volume of untreated CSO discharges upstream in the collection system. A justification is required for the cut off point for secondary bypasses and/or a feasible alternatives assessment for the secondary bypasses. Appendix J of the LTCP addresses some WWTP improvements but does not mention anything about expansion of primary or secondary capacity. (ACSD, RCSD) GENERAL COMMENTS: (ALL) The Best Management Practices and implementation of the 9 minimum (or 15 minimum as numerated in the conditions in the permits) controls have not been fully developed. Many of the items in the LTCP should have been completed under a fully executed BMP. For example, the Dry Weather Overflows (DWOs) should have been addressed under the BMPs. The projects identified are expected to meet water quality standards and attain the best usage for the Xxxxxx River in the Albany Pool area. Revise the sequencing of the projects to address projects with the greatest benefit(s) first. The Proposed Implementation Schedule (Figure 9-3), needs to be modified to group projects into sub-categories that can easily be put into a schedule of compliance/consent order for the individual permits for the communities. Consideration of sensitive areas. There is no specific discussion of sensitive areas. However, the compliance strategy is based on achieving water quality standards at two potential beach sites during the recreation season. These beach sites could reasonably be assumed to be the sensitive areas of concern. The LTCP should refer to these sites as sensitive areas, and properly address them as such in accordance with the EPA CSO Policy and guidance. Wet Weather Operational Plan. There is no explicit operation plan included in the LTCP, nor is their explicit discussion of the future operation of the collection system and the WWTPs to manage CSOs or minimize their impacts. The LTCP needs to refer to status of BMP #5 (an approved Wet Weather Operating Plan) for each of the three sewer districts. Additionally, there needs to be an inter-municipal wet weather operating plan for the CSS to control and minimize CSOs. Justification for “laterally well-mixed” assumption. The Albany Pool LTCP treats the Xxxxxx River as laterally well-mixed in the ...
AutoNDA by SimpleDocs
Wastewater Treatment Plant Improvements. Submitted plans to Ohio EPA (for PTI). Comments were received from Ohio EPA and have been addressed. Ohio EPA Permit to Install was issued. Project is being expanded to include additional improvements to increase plant capacity. Design Phase Design is progressing. PRIVATE DEVELOPMENT PROJECTS Ravines at Meadow Ridge (DRK Apartments) Metro Development (DRK) submitted an application to rezone 67.1 acres of land between Africa Road and 3 B’s & K Road, on the south side of 36/37, to Planned Residence District (PRD) and to rezone 2.0 acres of land on the east side of 3 B’s & K Road, on the south side of 36/37, to Planned Commercial District (PCD). Metro Development proposes to construct 744 apartments, with ancillary supporting facilities, within the PRD. Design Phase Construction drawings are being prepared.

Related to Wastewater Treatment Plant Improvements

  • School Improvement Plans The School shall develop and implement a School Improvement Plan as required by section 1002.33(9)(n), Florida Statutes and applicable State Board of Education Rules or applicable federal law.

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • Improvement Plans a. An improvement plan is a clearly articulated assistance program for a teacher/counselor/SLP whose overall summative rating is ineffective.

  • School Improvement Plan As permitted under IC § 20-10.2-3-1.5, the Charter shall serve as the Charter School's strategic and continuous school improvement and achievement plan (hereafter, the "School Improvement Plan"). To the extent that IC § 20-10.2 applies to the Charter in its function as the School Improvement Plan, the Organizer shall comply with the requirements under IC § 20-10.2.

  • Project Site The “Project Site” is the place where the Work is being carried on.