Facility Operation and Maintenance Sample Clauses

Facility Operation and Maintenance. Seller shall operate and maintain its Facility according to prudent electrical practices, applicable laws, orders, rules, and tariffs and shall provide such reactive power support as may be reasonably required by PGandE to maintain system voltage level and power factor. Seller shall operate the Facility at the power factors or voltage levels prescribed by PGandE's system dispatcher or designated representative. If Seller fails to provide reactive power support, PGandE may do so at Seller's expense.
AutoNDA by SimpleDocs
Facility Operation and Maintenance. Operation and maintenance of the Charter School's facility (the "Facility") to the extent consistent with any and all leases or other documents pertaining to the Facility;
Facility Operation and Maintenance. Generator must supply, manage, control, operate, and maintain the Facility at its own expense, including suitable maintenance of the Access Route throughout the Term, to allow GPC access in accordance with Section 1.3.A (Access Route). Each time the Facility operationally connects (“closes in”) to the Electric System, Generator is solely responsible for ensuring proper synchronization between the Facility and the Electric System. Generator also must maintain written or electronic operational, testing, and maintenance records as required to meet NERC audit schedules for generator owners or any other applicable regulatory requirement, which records GPC may review upon reasonable request. Throughout the Term, GPC may assess the Facility for compliance with this QFIA and Generator must cooperate with GPC in the scheduling and performance of any periodic or other assessment.
Facility Operation and Maintenance. Section 8(a) is hereby amended by deleting the final sentence of such section and replacing such sentence with the following: "The Lessee shall not sell any electricity generated by the Facility except to the Power Purchaser as provided in the Power Purchase Agreement or PPC as provided in the PPC Assignment and Exclusive Sales Agreement."
Facility Operation and Maintenance. The Lessee shall: (i) maintain the Facility in such condition that it will have the capacity and functional ability to perform on a continuing basis, in normal commercial operation, the functions for which it was designed, ordinary wear and tear excepted; (ii) operate, service, maintain, overhaul, test and repair the Facility and any Modifications and replace all necessary or useful parts and components thereof so that the condition and operating efficiency of the Facility and any Modification will be maintained and preserved in all respects in accordance with (A) Prudent Utility Practice, (B) such operating standards as shall be required to take advantage of and enforce all available warranties, (C) the terms and conditions of all insurance policies required to be maintained pursuant to Section 10 hereof and (D) the terms and conditions of the Power Purchase Agreement; (iii) use, possess, operate and maintain the Facility, any Modification, the Site and the Easements in compliance with all Applicable Laws and Governmental Actions affecting the Facility, any Modification, the Site or the Easements or the use, possession, operation and maintenance thereof except for such noncompliance as would not subject Lessor, Lessee, Owner Participant, Administrative Agent, Indenture Trustee or any Loan Participant to criminal or material civil liability and as would not have or would not reasonably be expected to have a material adverse effect on the Facility or the ability of the Lessee or any other Person to perform its obligations under any Transaction Document to which it is or will become a party; and (iv) maintain all records, logs, manuals and other materials in respect of the Facility, any Modification, the Site and the Easements in accordance with Prudent Utility Practice. Subject to Section 8(h) hereof, the Lessee shall comply, and shall cause the Operator to comply, with all the Lessee's obligations under Applicable Laws (including, without limitation, the CPCN) affecting the Facility, any Modification, the Site and the Easements. The Lessee shall not permit the Facility to be maintained, used or operated in any manner or for any purpose excepted from any insurance in respect of the Facility. The Lessee shall not omit to take any action necessary to cause the Facility to be maintained, used or operated in any manner or for any purpose excepted from any insurance in respect of the Facility. The Lessee shall not permit the Facility to be maintained, used or op...
Facility Operation and Maintenance. Coordinate the operation and maintenance of the Academy's facility (the "Facility") to the extent consistent with any and all leases or other documents pertaining to the Facility. Unless approved by the Board, the Academy Facility shall only be used to carry out the terms and conditions of the Charter and or educational purposes not inconsistent with the Charter, such as a before school and after school child care program. The Board and Operator shall consult with one another before the Board purchases, leases or modifies the Academy Facility. If the Board does not own the Facility, Operator will review any lease between the Board and its lessor for the Academy Facility (the “Lease”). In connection with its duty to administer and operate the Academy, Operator, on behalf of the Board agrees to operate in compliance with the Lease and to immediately notify the Board, in the event that Operator acts or fails to act in any manner which would result in a breach or default by the Board under the terms of the Lease.
Facility Operation and Maintenance. Managing, supervising, operating, and maintaining the Facility, employing Good Electrical Practice, in accordance with this Agreement, the Interconnection Agreement and other Project Agreements, including the day-to-day management of the Facility and the management of any maintenance and service work on the Equipment but excluding performing any such maintenance and service work on the Equipment, it being understood that such maintenance and service work on the Equipment is the responsibility of the Equipment Suppliers pursuant to the relevant Project Agreements. The Company shall provide an operating and maintenance building on the Facility Site in which the Contractor’s personnel may perform certain of their duties.
AutoNDA by SimpleDocs
Facility Operation and Maintenance. 16 6.1 Facility Operations and Control 16 6.2 Facility Planned Outages/Maintenance. 16 6.3 Forced Outages 17 6.4 Outage Reporting 18 6.5 Capacity Accreditation 18 6.6 Obligation to Rebuild 18 7.1 Billing Statement and Invoices 18 7.2 Payments 19 7.3 Billing Disputes 19 7.4 Billing and Payment Records 19 7.5 Wire Transfer 19 7.6 Curtailments 20 8.1 Pre-COD Reporting Obligations 21 8.2 Post-Construction Information. 22 8.3 Operating Committee and Operating Procedures 23 8.4 Wind Data and Capacity. 24
Facility Operation and Maintenance 

Related to Facility Operation and Maintenance

  • Operation and Maintenance 17.1 O&M obligations of the Concessionaire 17.1.1 During the Operation Period, the Concessionaire shall operate and maintain the Bus Terminal in accordance with this Agreement either by itself, or through the O&M Contractor and if required, modify, repair or otherwise make improvements to the Bus Terminal to comply with the provisions of this Agreement, Applicable Laws and Applicable Permits, and conform to Specifications and Standards and Good Industry Practice. The obligations of the Concessionaire hereunder shall include: (a) permitting safe, smooth and uninterrupted flow of traffic on the Bus Terminal during normal operating conditions. Buses of other state road transport corporations shall be parked inside the Bus Terminal for which no charges shall be payable to the Concessionaire and if any charges are applicable for such parking then it shall be realized by Authority only; (b) minimising incidents affecting the safety and use of the Bus Terminal by providing a rapid and effective response and maintaining liaison with emergency services of the State; (c) carrying out periodic preventive maintenance of the Bus Terminal; (d) undertaking routine maintenance including prompt repairs of ticket counters, Workshops, Authority's Office and other infrastructure as mentioned in the Operation and Maintenance Schedule; (e) undertaking major maintenance such as per the Maintenance Schedule of the major infrastructure in the Bus Terminal; (f) preventing, with the assistance of the concerned law enforcement agencies, any encroachments on the Bus Terminal; (g) protection of the environment and provision of equipment and materials therefor; (h) operation and maintenance of all communication, control and administrative systems necessary for the efficient operation of the Bus Terminal; (i) maintaining a public relations unit to interface with and attend to suggestions from the Users, passengers, government agencies, media and other agencies; (j) complying with Safety Requirements in accordance with Article 18; (k) operation and maintenance of all Project Assets diligently and efficiently and in accordance with Good Industry Practice; (l) maintaining punctuality and reliability in operating the Bus Terminal; and (m) maintaining a high standard of cleanliness and hygiene in the Bus Terminal. 17.1.2 The Concessionaire shall remove promptly from the Bus Terminal all surplus construction machinery and materials, waste materials (including hazardous materials and waste water), rubbish and other debris (including, without limitation, accident debris) and keep the Bus Terminal in a clean, tidy and orderly condition,

  • Operations and Maintenance Seller shall not during the months of June through September inclusive schedule any non-emergency maintenance that reduces the energy generating capability of the Facility by more than ten percent (10%), unless (i) such outage is required to avoid damage to the Facility, (ii) such maintenance is necessary to maintain equipment warranties and cannot be scheduled outside the months of June through September, (iii) such outage is required in accordance with prudent electrical practices, or (iv) the Parties agree otherwise in writing.

  • Operation and Maintenance Manuals Receipts for transmittal of Operation and Maintenance Manuals, Brochures and Data to the Design Professional (or Commissioning Agent) as required by Section 6.1.1.5.

  • Construction and Maintenance There are on-going maintenance, renovation and construction projects taking place in and around the residences. The work typically takes place during regular business hours, but may begin earlier or extend into evenings or weekends. On-going construction or renovation projects will continue through midterm and final exam periods. The University will take measures to ensure that prudent construction practices are followed, but there may be noise, dust and temporary interruption of some services. Residents may be required to temporarily or permanently relocate to facilitate construction or renovation to their residence area. There will be no compensation or reduction to your residence fees due to disruption and/or relocation.

  • Installation and Maintenance Except for the bi‐directional and production metering equipment owned by the City, all equipment on Customer’s side of the delivery point, including the required disconnect device, shall be provided and maintained in satisfactory operating condition by Customer and shall remain the property and responsibility of the Customer. The City will bear no responsibility for the installation or maintenance of Customer’s equipment or for any damage to property as a result of any failure or malfunction thereof. The City shall not be liable, directly or indirectly for permitting or continuing to allow the interconnection of the Facility or for the acts or omissions of Customer or the failure or malfunction of any equipment of Customer that causes loss or injury, including death, to any party.

  • Support and Maintenance Where Licensee purchases support and/or maintenance services, Licensee’s initial support and/or maintenance term will begin upon delivery to Licensee of the Licensed Software and continue for one (1) year thereafter (or the length of the term if less than a year for any subscription/term license) unless otherwise specified in the applicable annual support and/or maintenance agreement, Product Order, or other written agreement executed between Licensor and Licensee. Where Licensee purchases support and/or maintenance for any Licensed Software, Licensee hereby agrees that it shall purchase such support and/or maintenance services for all of Licensee’s licensed units of such Licensed Software product. Support and/or maintenance services provided by Licensor will be subject to Licensor’s then current applicable standard annual support and/or maintenance agreement unless otherwise agreed by the parties in writing.

  • Planned Maintenance (a) Subject to any modification or amendment of this Agreement made pursuant to Section 4.2(c) or Section 7.3(d), Planned Maintenance occurring during the Delivery Term shall be coordinated and scheduled in accordance with this Section 9.6. Seller shall perform all Planned Maintenance (including Major Planned Maintenance) in a manner that optimizes the generation and benefits to Buyer of the Contract Energy, Storage Energy, and other Products (e.g., during off-peak periods and low-irradiance periods) and, without limiting the foregoing, either (i) outside of Daylight Hours or (ii) during the months of October and November only, during Daylight Hours; provided, however, that the foregoing restrictions shall not apply to any Planned Maintenance that Seller is required to perform pursuant to any applicable manufacturer warranty that cannot reasonably be performed by Seller subject to such restrictions. (b) Seller shall deliver to Buyer a proposed schedule for Planned Maintenance in respect of each Contract Year (“Planned Maintenance Schedule”) no later than ninety (90) Days before the start of such Contract Year. Planned Maintenance Schedules submitted by Seller shall (i) comply with the second sentence of Section 9.6(a) and (ii) include reasonably detailed descriptions of the Planned Maintenance to be performed, the Days and times in which each type of Planned Maintenance is scheduled to be performed, the estimated amount(s) of Contract Capacity and Storage Capacity that will be unavailable due to Planned Maintenance and the total number of hours that Seller expects that the Contract Capacity and Storage Capacity will be unavailable due to Planned Maintenance. The general form for the Planned Maintenance Schedule is set forth in Schedule 9.6. (The Planned Maintenance descriptions reflected in the general form set forth in Schedule 9.6 are provided for indicative purposes only, and are not necessarily representative of the detail, time periods, or certainty required for a Planned Maintenance Schedule hereunder.) (c) Buyer shall have the right to disapprove, in its reasonable discretion (provided that Buyer shall have the right to disapprove, in its sole and absolute discretion, any Planned Maintenance proposed by Seller that is inconsistent with the terms of this Agreement), any Planned Maintenance set out in any Planned Maintenance Schedule proposed by Seller for any Contract Year, except for any Planned Maintenance that (i) is scheduled to occur outside of Daylight Hours or during Daylight Hours during the months of October and November or (ii) Seller is required to perform pursuant to any applicable manufacturer warranty and that is scheduled to occur in compliance with Section 9.6(a). If Seller submits its Planned Maintenance Schedule for a Contract Year in accordance with the requirements of this Agreement and Buyer does not disapprove of any Planned Maintenance set out in such Planned Maintenance Schedule by sixty (60) days after submission, then such Planned Maintenance Schedule shall be deemed approved. If Buyer, in the exercise of its discretion as set forth above, disapproves any Planned Maintenance in such Planned Maintenance Schedule within the applicable time period specified above after its submission, Buyer shall notify Seller and the Parties shall use Commercially Reasonable Efforts to agree upon and finalize a mutually acceptable Planned Maintenance Schedule for the applicable Contract Year. Seller shall conduct Planned Maintenance during such Contract Year only in accordance with an agreed Planned Maintenance Schedule; provided, however, that Seller may (A) move Planned Maintenance included in an agreed Planned Maintenance Schedule that is not Major Planned Maintenance, so long as such move is consistent with the terms of this Agreement (including the second sentence of Section 9.6(a)) or, with respect to Major Planned Maintenance, if such Major Planned Maintenance is scheduled to occur outside of Daylight Hours or during Daylight Hours during the months of October and November and (B) schedule and perform Planned Maintenance not reflected in the Planned Maintenance Schedule so long as such Planned Maintenance is scheduled to be performed outside of Daylight Hours or during Daylight Hours during the months of October and November and Seller provides Buyer at least two (2) weeks’ prior written notice of such Planned Maintenance; provided further that Buyer shall have the right to advise Seller of periods when Buyer prefers, based on solar irradiance, supply, market and other conditions, that any Major Planned Maintenance be deferred, and Seller shall use Commercially Reasonable Efforts to comply with such request. (d) Seller shall use Commercially Reasonable Efforts to complete any Planned Maintenance and place the Facility back into full commercial operation as soon as reasonably possible. If Seller determines that any Planned Maintenance scheduled in an agreed Planned Maintenance Schedule no longer needs to be completed or will not consume the entire time scheduled therefor in the agreed Planned Maintenance Schedule, Seller shall provide (i) a Generation Forecast to Buyer reflecting the forecasted amount of Delivered Energy during each affected interval that takes into account such change and (ii) in the case of any Major Planned Maintenance, a written notice declaring the cessation and termination of the applicable Major Planned Maintenance period (in which event, the Major Planned Maintenance period shall terminate in accordance with the terms of such Generation Forecast and written notice).

  • Operations and Maintenance Notice Developer and Connecting Transmission Owner shall each notify the other Party, and NYISO, in writing of the identity of the person(s) that it designates as the point(s) of contact with respect to the implementation of Articles 9 and 10 of this Agreement.

  • Account Maintenance Trade Allocations Trade Reporting; (Futures) Daily Trade Checkout Daily Statement Reconciliation

  • Operation and Maintenance of Properties The Borrower will, and will cause each of its Subsidiaries to: (a) operate its Oil and Gas Properties and other material Properties or cause such Oil and Gas Properties and other material Properties to be operated in a careful and efficient manner in accordance with the practices of the industry and in compliance with all applicable contracts and agreements and in compliance with all Governmental Requirements, including, without limitation, applicable proration requirements and Environmental Laws, and all applicable laws, rules and regulations of every other Governmental Authority from time to time constituted to regulate the development and operation of its Oil and Gas Properties and the production and sale of Hydrocarbons and other minerals therefrom, except, in each case, where the failure to comply could not reasonably be expected to have a Material Adverse Effect. (b) keep and maintain all Property material to the conduct of its business in good working order and condition, ordinary wear and tear excepted preserve, maintain and keep in good repair, working order and efficiency (ordinary wear and tear excepted) all of its material Oil and Gas Properties and other material Properties, including, without limitation, all material equipment, machinery and facilities. (c) promptly pay and discharge, or make reasonable and customary efforts to cause to be paid and discharged, all delay rentals, royalties, expenses and indebtedness accruing under the leases or other agreements affecting or pertaining to its Oil and Gas Properties and will do all other things necessary to keep unimpaired their rights with respect thereto and prevent any forfeiture thereof or default thereunder. (d) promptly perform or make reasonable and customary efforts to cause to be performed, in accordance with industry standards and in all material respects, the obligations required by each and all of the assignments, deeds, leases, sub-leases, contracts and agreements affecting its interests in its Oil and Gas Properties and other material Properties. (e) to the extent the Borrower or one of its Subsidiaries is not the operator of any Property, the Borrower shall use reasonable efforts to cause the operator to comply with this Section 8.06.