Hvac Specifications Sample Clauses

Hvac Specifications. Landlord agrees that the air-conditioning system in the portion of the Leased Premises consisting of Office Space will be capable of providing, and (unless otherwise ordered by federal, state or local governmental authorities) the system shall provide, temperatures of nor more than 77°F dry bulb and a relative humidity not in excess of 50% with outside conditions of 95°F dry bulb and 78°F wet bulb, except as otherwise provided in this subsection. Landlord agrees that the heating system in the portion of the Leased Premises consisting of Office Space will be capable of providing, and (unless otherwise ordered by federal, state or local governmental authorities) the system shall provide, temperatures of not less than 70°F whenever the outdoor dry bulb temperature is lower than 65°F but no lower than 0°F, with indoor relative humidity at such level as not to permit the formation of condensation on the windows. Landlord shall not be responsible if the normal operation of the Building air-conditioning system shall fail to provide conditioned air at reasonable temperatures, pressures or degrees of humidity or in reasonable volumes or velocities in any portions of the Leased Premises consisting of Office Spice which (i) shall have a connected electrical load in excess of three xxxxx per square foot of Rentable Area of the Leased Premises for all purposes (including lighting and power) or which shall have a human occupancy factor in excess of one person for each 100 square feet of Rentable Area of the portion of the Leased Premises consisting of Office Space (the average electrical load and human occupancy factors for which the Building air-conditioning system is designed), or (ii) because of rearrangement of partitioning or other Alterations made by or on behalf of Tenant or any Person claiming, through or under Tenant (excepting work performed by Landlord for Tenant prior to Tenant’s initial occupancy of the Leased Premises).
AutoNDA by SimpleDocs
Hvac Specifications. Landlord represents to Tenant that the HVAC system for the Leased Premises has been designed to provide for the comfortable occupancy of the Leased Premises at temperatures consistent with those provided in Peer Group Buildings, subject to Legal Requirements. Landlord shall not be responsible if the normal operation of the Building air-conditioning system shall fail to provide conditioned air within comfortable temperatures levels (i) in any portions of the Leased Premises which have a connected electrical load for all purposes (including lighting and power) in excess of eight (8) xxxxx per square foot of Rentable Area or which have a human occupancy factor in excess of one individual for each one hundred (100) square feet of Rentable Area (the average electrical load and human occupancy factors for which the Building air-conditioning system is designed), (ii) because of the rearrangement of partitioning or other Alterations made by or on behalf of Tenant or any Person claiming through or under Tenant, or (iii) because of the failure by Tenant or its employees to use the HVAC system in the manner in which it was designed to be used. Tenant agrees to observe and comply with all reasonable rules from time to time prescribed by Landlord for the proper functioning and protection of the HVAC systems in the Building.
Hvac Specifications. HVAC systems shall meet the following design conditions at the staled outside conditions with the Premises being utilized when average occupancy is not more than one person per 000 xxxxxx xxxx xx xxxxxx xxxxx xxxx:
Hvac Specifications. Landlord shall provide a high quality air-conditioning system on a year-round basis throughout the useable office area of the Premises. Interior space shall be provided with thermostatically controlled zones. The system shall maintain an average inside temperature of 75° +/- 2 degrees during summer outdoor temperatures of 99° F.D.B. and 78° F.W.B. and 72° +/- 2° F.D.B. at winter outside temperatures of 19° F.D.B. and in accordance with an occupancy of one person per 250 square feet (average per floor) and an electrical connected load of 4 xxxxx per useable square foot of the Premises, for Tenant's use. These temperatures are subject to the conditions and requirements of State and Federal Energy Regulating Bodies for non-residential buildings (collectively, "regulatory requirements"). All conditions are 1989 ASHRAE Standard for energy conservation and Building design. EXHIBIT J This Exhibit J is attached to and made a part of that certain Lease Agreement (the "Lease") dated as of 2006, by and between ("Landlord"), and SABRE INC., a Delaware corporation ("Tenant"). All capitalized terms used but not defined herein shall have the meaning assigned to them in other portions of the Lease.
Hvac Specifications. The following table has been prepared to provide the location of Tenant Contractor specific information within the Base Building Specifications 720213.12/XXX000000-00005/4-9-14/mem/ejw SCHEDULE 3-15- TI Material & Equipment Base Building Specification Section Ductwork 23 31 00 – Ductwork and Sheet Metal Piping 23 21 13 – Pipes, Valves, Fittings, & Accessories Hydrostatic Testing 23 05 93- Section 3.3 D VAV Fan Powered Terminal Unxxx 00 00 00- Xxx Xxxxxxxx Xnits Grills, Registers, and Diffusers 23 37 00– Air Distribution Equipment Mechanical Insulation 23 07 00- Thermal Insulation Offices – cooling inside design condition 23 05 07 – Design Conditions Offices – heating inside design condition 23 05 07 – Design Conditions Testing & Balancing 23 05 93 – Testing, Balancing, & Adjusting Plumbing Specification The point of connection for sanitary and vent lines will be available as a capped stub-out at 3 locations on each floor. The domestic water line point of connection will be capped and valved outside elevator lobby. The following table has been prepared to provide the location of Tenant Contractor specific information within the Base Building Specifications TI Material & Equipment Base Building Specification Section Sanitary Waste/Vent Piping 221300 – Sewage and Drainage Systems Water Piping 221130- Recycled Water Systems22 10 00- Xxxxxxxx Xxxxx Xxxxxxx Xxxxx xrains, Plumbing Fixtures 224000- Clean-outs, Drains, & Plumbing Fixtures Pipe Insulation 220700 – Thermal Insulation Fire Sprinkler Specification A primary fire sprinkler system will be installed at each floor by the Base Building Contractor. Modifications to lower, relocate, and install vertical sections of pipe will be the responsibility of the tenant design/build contractor. The following table has been prepared to provide the location of Tenant Contractor specific information within the Base Building Specifications TI Material & Equipment Base Building Specification Section Sprinkler Piping 211300- Fire Suppression Sprinkler Systems Design/Build Drawings & Calculation Requirements 211300- Fire Suppression Sprinkler Systems Hangers & Supports 211300- Fire Suppression Sprinkler Systems Pipe joints/fittings 211300 – Fire Suppression Sprinkler Systems 720213.12/XXX000000-00005/4-9-14/mem/ejw SCHEDULE 3-15- Electrical & Telephone/Data Specification An electrical room will be available on each floor. Included in the electrical room will be a 200 A fused disconnect that will serve a 277/480 V lighting pan...
Hvac Specifications. OUTSIDE TEMPERATURE INDOOR TEMPERATURE ------------------- ------------------ SUMMER 75-94 degrees F. dry bulb 74-76 degrees F. at 50% relative humidity WINTER 55-74 degrees F. wet bulb 72-76 degrees F. assuming no humidification Floors Floors will be leveled so there is no more than a 1/4 inch variation for every ten feet to the extent needed to implement Tenant's architectural design or installation of systems. Security A card reading system will be located at the ground floor building entry, delivery and one passenger elevator and delivery door entrance. Windows Floor Load Bearing Capacity 100 lbs per square foot live load.
Hvac Specifications 
AutoNDA by SimpleDocs

Related to Hvac Specifications

  • Technical Specifications Each Bloom System is an integrated system comprised of a fuel cell stack assembly and associated balance of plant components that converts a fuel into electricity using electrochemical means that (i) has a Nameplate Capacity of at least 0.5 kilowatts of electricity using an electrochemical process and (ii) has an electricity-only generation efficiency greater than thirty percent (30%).

  • Quality Specifications SANMINA-SCI shall comply with the quality specifications set forth in its Quality Manual, incorporated by reference herein, a copy of which is available from SANMINA-SCI upon request.

  • Specifications Shipper will ensure that all of its Products tendered at the Origin Point for transportation on the Pipeline System meet the applicable specifications for the Product as set forth in the Tariff (as defined below) (the “Specifications”).

  • Changes to Specifications All Specifications and any changes thereto agreed to by the parties from time to time shall be in writing, dated and signed by the parties. Any change to the Process shall be deemed a Specification change. No change in the Specifications shall be implemented by Catalent, whether requested by Client or requested or required by any Regulatory Authority, until the parties have agreed in writing to such change, the implementation date of such change, and any increase or decrease in costs, expenses or fees associated with such change (including any change to Unit Pricing). Catalent shall respond promptly to any request made by Client for a change in the Specifications, and both parties shall use commercially reasonable, good faith efforts to agree to the terms of such change in a timely manner. As soon as possible after a request is made for any change in Specifications, Catalent shall notify Client of the costs associated with such change and shall provide such supporting documentation as Client may reasonably require. Client shall pay all costs associated with such agreed upon changes. If there is a conflict between the terms of this Agreement and the terms of the Specifications, this Agreement shall control. Catalent reserves the right to postpone effecting changes to the Specifications until such time as the parties agree to and execute the required written amendment.

  • Product Specifications The Company agrees that all Products sold to Xxxx hereunder shall conform to the respective specifications set forth on Schedule A or to such other specifications as are from time to time agreed upon by the Parties.

  • Specification Changes (a) During the Term, GSK will accept a labeling change from Prometheus as contemplated by this Section 4.2 but otherwise the Parties acknowledge and agree that GSK does not intend to make any material changes (such as packaging design, manufacturing process or similar or related changes) to the existing Product during the Term.

  • Plans and Specifications Tenant shall be solely responsible for the preparation of the final architectural, electrical and mechanical construction drawings, plans and specifications (called “plans”) necessary for Tenant to construct the Premises for Tenant’s occupancy, which plans shall be subject to approval by Landlord’s architect and engineers and shall comply with their reasonable requirements to avoid aesthetic or other conflicts with the design and function of the balance of the Building. Landlord’s approval is solely given for the benefit of Landlord, and neither Tenant nor any third party shall have the right to rely upon Landlord’s approval of Tenant’s plans for any purpose whatsoever other than that Landlord does not object thereto under this Lease. Landlord’s architects and engineers shall respond (with approval or disapproval) to any plan submission by Tenant within 8 business days after Landlord’s receipt thereof. If Landlord fails to respond to any such submission within such 8 business day period, which failure continues for more than 2 business days after Tenant gives Landlord a written notice (the “Deemed Approved Notice”) advising Landlord that such plan submission shall be deemed approved within 2 business days of Landlord’s receipt of the Deemed Approved Notice, then such plan submission shall be deemed approved hereunder. The Deemed Approved Notice shall, in order to be effective, contain on the first page thereof, in a font at least twice as large as the font of any other text contained in such notice, a legend substantially as follows: “FAILURE TO RESPOND TO THIS NOTICE WITHIN TWO (2) BUSINESS DAYS AFTER RECEIPT HEREOF SHALL CONSTITUTE LANDLORD’S APPROVAL OF SUBMITTED PLANS.” In the event Landlord’s architect’s or engineers’ approval of Tenant’s plans is withheld or conditioned, Landlord shall send prompt written notification thereof to Tenant and include a reasonably detailed statement identifying the reasons for such refusal or condition, and Tenant shall promptly have the plans revised by its architect to incorporate all reasonable objections and conditions presented by Landlord and shall resubmit such plans to Landlord. Landlord’s architects and engineers shall respond (with approval or disapproval) to any plan re-submission by Tenant within 8 business days after Landlord’s receipt thereof. Such process shall be followed until the plans shall have been approved by Landlord’s architect and engineers without unreasonable objection or condition. Without limiting the foregoing, Tenant shall be responsible for all elements of the design of Tenant’s plans (including, without limitation, compliance with law, functionality of design, the structural integrity of the design, the configuration of the Premises and the placement of Tenant’s furniture, appliances and equipment), and Landlord’s approval of Tenant’s plans shall in no event relieve Tenant of the responsibility for such design. Tenant agrees it shall be solely responsible for the timely preparation and submission of all such plans and for all elements of the design of such plans and for all costs related thereto. (The word “architect” as used in this Section 3.2 shall include an interior designer or space planner.) Tenant shall reimburse Landlord Landlord’s reasonable out-of-pocket expense incurred in connection with the review of Tenant’s plans.

  • Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.

  • Building Services To install, use and maintain through the Premises, pipes, conduits, wires and ducts serving the Building, provided that such installation, use and maintenance does not unreasonably interfere with Tenant's use of the Premises.

  • HVAC A. Heating, ventilating and air conditioning equipment will be provided with sufficient capacity to accommodate a maximum population density of one (1) person per one hundred fifty (150) square feet of useable floor area served, and a combined lighting and standard electrical load of 3.0 xxxxx per square foot of useable floor area. In the event Tenant introduces into the Premises personnel or equipment which overloads the system’s ability to adequately perform its proper functions, Landlord shall so notify Tenant in writing and supplementary system(s) may be required and installed by Landlord at Tenant’s expense, if within fifteen (15) days Tenant has not modified its use so as not to cause such overload. Operating criteria of the basic system shall not be less than the following:

Time is Money Join Law Insider Premium to draft better contracts faster.