Construction of the Plant Sample Clauses

Construction of the Plant. 5.2.1 The Concessionaire shall commence and prosecute, or shall procure the commencement and prosecution of, the EPC Works as soon as reasonably practicable following the Effective Date.
AutoNDA by SimpleDocs
Construction of the Plant. 7Design, procurement and installation of the Plant
Construction of the Plant. Provided *, and subject to final negotiation, execution and delivery of the Ancillary Agreements (key terms or concepts of which are set forth in the attached Exhibits) by the Parties, Bunge and Solazyme will cause the Company to build the Plant.
Construction of the Plant. The Company shall be responsible for the financing, design and construction of the Plant and the procurement, installation and commissioning of equipment therein. The Company shall make all reasonable efforts to begin initial syngas production by June/July 2007 and enter Commercial Operation in August/September 2007.
Construction of the Plant. 2.01 Cogenerator to Construct. Cogenerator will, at its sole cost and expense, design, construct and complete, on land near Big Spring, Xxxxxx County, Texas, a cogeneration facility consisting of two gas-combustion turbines and one steam turbine with a net electrical generating capacity of approximately 106 megawatts (MW) together with all necessary and desirable buildings, equipment and facilities, hereinafter referred to as the "Plant". The Plant will be designed and constructed in compliance with legal and regulatory, including environmental,
Construction of the Plant. Article 51 The JV Company may employ a third party construction contractor to construct the Plant. The Board of Directors shall be entitled to appoint an independent supervising engineer to oversee the performance of the relevant contractors and sub-contractors under the construction contract. In addition, each Party shall be entitled to appoint a site representative engineer, whose responsibilities shall include the monitoring of construction, staff training and health and safety matters and witnessing of commissioning and relevant testing of the Plant.
Construction of the Plant. Design, procurement and installation of the Plant The Contractor shall, at its own cost, design and procure the Plant and carry out the installation, completion, testing and commissioning of the Plant at the Plant Site for production of electricity from the Full Commercial Operation Date in accordance with all applicable laws and regulations, and consistent with the technical specifications set forth in Annex B including the performance ratio of the Plant.2 The Contractor shall install the Plant for the proper and safe interconnection of the Plant to the Existing Electrical System necessary to transmit and deliver the energy output at the Delivery Point. The Parties agree that the Full Commercial Operation Date is on [DD.MM.YYYY]. The Contractor shall begin the design, installation, completion, testing and commissioning of the Plant at the latest on the Effective Date to achieve the Full Commercial Operation Date. The Contractor may engage subcontractors to meet any obligation under the Agreement. The engagement of subcontractors does not limit Contractor’s liability and its obligations arising from the Agreement. Any subcontractor engaged by Contractor to perform any portion of the obligations under the Agreement shall have all licenses and registrations required to perform this kind of services and all insurance obligations as required pursuant to Section 6 shall be fulfilled and maintained by the Contractor and its subcontractors for the entire duration of the Agreement. Commissioning and Testing The Contractor shall be responsible for commissioning and testing of the Plant. The Contractor shall carry out commissioning and testing in accordance with Prudent Operating Practice and any procedure agreed on by the Parties. The Plant shall be ready for regular daily operation and Contractor shall have finalised commissioning and testing by the Full Commercial Operation Date. The Contractor shall give at least [seven (7)] day’s prior notice to the Client of the date of commencement of commissioning and testing of the Plant. The Client shall have the right to be present at the Site and to inspect and witness the commissioning and testing. After one (1) year of operation the defined performance ratio of the Plant will be confirmed. The Client shall cooperate with the Contractor so as to enable the Contractor to commission and test the Plant in accordance with this Section. Access to the Site and the Plant For the purpose of designing and constructing the Plant,...
AutoNDA by SimpleDocs
Construction of the Plant. 5.13.1 The SPD shall construct the Solar Power Project as per the technical specification provided in bid / tender document. The SPD shall be responsible for the correct positioning of all parts of the Works, and shall rectify any error in the Works. From the Appointed Date shall be the scheduled completion date (the “Scheduled Completion Date”) and the Contractor agrees and undertakes that the construction shall be completed on or before the Scheduled Completion Date, including any extension thereof. 5.13.2 The SPD shall construct the Solar Power Project in accordance with the Project Completion Schedule set forth in RfS. In the event, that the SPD fails to achieve any Project Milestone or the Scheduled Completion Date within the specified days from the date, unless such failure has occurred due to Force Majeure or for reasons solely attributable to the APDCL, it shall pay Damages to the APDCL as per terms and conditions stipulated in this agreement

Related to Construction of the Plant

  • Condition of the Property THE LESSEE ACKNOWLEDGES AND AGREES THAT IT IS LEASING THE PROPERTY "AS IS" WITHOUT REPRESENTATION, WARRANTY OR COVENANT (EXPRESS OR IMPLIED) BY THE LESSOR AND SUBJECT TO (A) THE EXISTING STATE OF TITLE, (B) THE RIGHTS OF ANY PARTIES IN POSSESSION THEREOF, (C) ANY STATE OF FACTS WHICH AN ACCURATE SURVEY OR PHYSICAL INSPECTION MIGHT SHOW, AND (D) VIOLATIONS OF REQUIREMENTS OF LAW WHICH MAY EXIST ON THE DATE HEREOF OR ON THE ACQUISITION DATE. THE LESSOR HAS NOT MADE AND SHALL NOT BE DEEMED TO HAVE MADE ANY REPRESENTATION, WARRANTY OR COVENANT (EXPRESS OR IMPLIED) AND SHALL NOT BE DEEMED TO HAVE ANY LIABILITY WHATSOEVER AS TO THE TITLE (OTHER THAN FOR LESSOR LIENS), VALUE, HABITABILITY, USE, CONDITION, DESIGN, OPERATION, OR FITNESS FOR USE OF THE PROPERTY (OR ANY PART THEREOF), OR ANY OTHER REPRESENTATION, WARRANTY OR COVENANT WHATSOEVER, EXPRESS OR IMPLIED, WITH RESPECT TO THE PROPERTY (OR ANY PART THEREOF) AND THE LESSOR SHALL NOT BE LIABLE FOR ANY LATENT, HIDDEN, OR PATENT DEFECT THEREIN (OTHER THAN FOR LESSOR LIENS) OR THE FAILURE OF THE PROPERTY, OR ANY PART THEREOF, TO COMPLY WITH ANY REQUIREMENT OF LAW.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!