Metering and Telemetry Sample Clauses

Metering and Telemetry a) Except as may be otherwise specifically provided for herein, electrical meters and associated equipment of the type approved by MSEDCL, which meters and equipment shall be installed on Generator’s premises at their cost and thereon owned, installed, operated and maintained by MSEDCL. Generator shall, at its own expense, furnish, install and maintain mounting facilities for such meters and associated devices located in the Dedicated Facilities. The Generator shall construct air-conditioned metering cabin of size 3.5 x 3.5 meter for housing energy and tariff metering. Special Energy Meters (ABT) with online reading features having continuous communication facility with SLDC shall be installed at the metering point. The utility / licensee, if opted for by the co-gen project entity, shall provide check meter, with identical specifications to that of main billing meter having independent CTs &PTs, at the cost of the project holder, to assess the energy generated and fed into the grid during such period when the main meter or its related accessories such as CT/PT fail or develop problems, so as to avoid disputes in future. Generator’s and MSEDCL’s electric metering equipment shall be sealed and the seals shall be broken only upon occasions when the meters are to be inspected, tested or calibrated before the representatives of Generator and MSEDCL , who shall be present upon such occasions. Normal inspection, testing and calibration shall be performed once a year, or at Generator’s expense, at more frequent intervals.
AutoNDA by SimpleDocs
Metering and Telemetry. Idaho Power shall, for the account of Seller, provide, install, and maintain Metering Equipment as required to determine the amount of Net Energy and Inadvertent Energy delivered to Idaho Power by the Transmitting Entity at the Point of Delivery. The metering will be installed at the location as specified in Appendix B of this Agreement. If required by Idaho Power, metering will also include measurement of kilovar-hours in a manner agreed to by both Parties. All customary and reasonable Metering Equipment and installation costs shall be borne by Seller, including costs incurred by Idaho Power for inspecting and testing such equipment at reasonable intervals at Idaho Power's actual cost of providing this Metering Equipment and services. All meters used to determine the billing hereunder shall be sealed and the seals shall be broken only by Idaho Power when the meters are to be inspected, tested or adjusted.
Metering and Telemetry a) Special Energy Meters (ABT) with online reading features having continuous communication facility with SLDC/ MSEDCL shall be installed at the metering point. The utility / licensee, if opted for by the co-gen project entity, shall provide check meter, with identical specifications to that of main billing meter having independent CTs &PTs, at the cost of the project holder, to assess the energy generated and fed into the grid during such period when the main meter or its related accessories such as CT/PT fail or develop problems, so as to avoid disputes in future. Generator’s and MSEDCL’s electric metering equipment shall be sealed and the seals shall be broken only upon occasions when the meters are to be inspected, tested or calibrated before the representatives of Generator and MSEDCL , who shall be present upon such occasions. Normal inspection, testing and calibration shall be performed once a year, or at Generator’s expense, at more frequent intervals.
Metering and Telemetry. The Buyer shall provide, install, and maintain Metering and Telemetry Equipment to be located at the Metering Point to accurately calculate the actual energy deliveries from the Seller to the Transmitting Entity at the Metering Point and provide continuous telemetry information from the Facility to the Buyer. The Metering and Telemetry Equipment shall be of the type required to accurately measure, record and report the energy to provide the Buyer adequate Net Energy and Test Energy measurement data to administer this Agreement and to integrate the Facility’s energy into the Buyer’s electrical system. The Seller shall be responsible for all costs of the actual Metering and Telemetry Equipment, installation, inspections, maintenance and testing costs.
Metering and Telemetry. The Cooperative shall be reimbursed for all costs of interconnection, including direct and indirect expenses related to metering and telemetry costs when needed, incurred by the Cooperative in connecting the Member generation facility to the distribution system. Metering shall meet accuracy standards required for equivalent electrical services and can be accomplished with standard meters or any devices that meet data collection and accuracy requirements. Recurring maintenance expenses incurred through the power or transmission supplier will be billed to the Member on an actual cost basis.
Metering and Telemetry a. Except as may be otherwise specifically provided for herein, electrical meters and associated equipment of the type approved by MSEDCL, which meters and equipment shall be installed on Generator’s premises at their cost and thereon owned, installed, operated and maintained by MSEDCL. Generator shall, at its own expense, furnish, install and maintain mounting facilities for such meters and associated devices located in the Dedicated Facilities. The Generator shall construct air-conditioned metering cabin of size 3.5 x 3.5 meter for housing energy and tariff metering.
Metering and Telemetry. All electric metering associated with a Solar Facility including the Project Meter, whether owned by PPAC or a third party, shall be installed, operated, maintained, and tested by or on behalf of PPAC in accordance with Good Utility Practices, and any applicable OFFTAKER technical requirements and standards.
AutoNDA by SimpleDocs

Related to Metering and Telemetry

  • Metering The Interconnection Customer shall be responsible for the Connecting Transmission Owner’s reasonable and necessary cost for the purchase, installation, operation, maintenance, testing, repair, and replacement of metering and data acquisition equipment specified in Attachments 2 and 3 of this Agreement. The Interconnection Customer’s metering (and data acquisition, as required) equipment shall conform to applicable industry rules and Operating Requirements.

  • Interconnection 2.1.10 Startup Testing and Commissioning

  • Compatibility 1. Any unresolved issue arising from a mutual agreement procedure case otherwise within the scope of the arbitration process provided for in this Article and Articles 25A to 25G shall not be submitted to arbitration if the issue falls within the scope of a case with respect to which an arbitration panel or similar body has previously been set up in accordance with a bilateral or multilateral convention that provides for mandatory binding arbitration of unresolved issues arising from a mutual agreement procedure case.

  • Network Access Control The VISION Web Site and the Distribution Support Services Web Site (the “DST Web Sites”) are protected through multiple levels of network controls. The first defense is a border router which exists at the boundary between the DST Web Sites and the Internet Service Provider. The border router provides basic protections including anti-spoofing controls. Next is a highly available pair of stateful firewalls that allow only HTTPS traffic destined to the DST Web Sites. The third network control is a highly available pair of load balancers that terminate the HTTPS connections and then forward the traffic on to one of several available web servers. In addition, a second highly available pair of stateful firewalls enforce network controls between the web servers and any back-end application servers. No Internet traffic is allowed directly to the back-end application servers. The DST Web Sites equipment is located and administered at DST’s Winchester data center. Changes to the systems residing on this computer are submitted through the DST change control process. All services and functions within the DST Web Sites are deactivated with the exception of services and functions which support the transfer of files. All ports on the DST Web Sites are disabled, except those ports required to transfer files. All “listeners,” other than listeners required for inbound connections from the load balancers, are deactivated. Directory structures are “hidden” from the user. Services which provide directory information are also deactivated.

  • Generator Subject to the provisions of this Section 29.36, Tenant shall be entitled to install, operate and maintain a generator and any other equipment related thereto, including, without limitation, a fuel system, wiring and shaft space (“Generator”) next to the Building at Tenant’s sole cost and expense (without paying any additional fee or rental to Landlord for the use thereof). Prior to the installation of the Generator, Tenant shall inspect the proposed location to determine a suitable location for the Generator, and Tenant shall submit written plans and specifications relative to the type, size and proposed location (including any proposed screening) of the Generator to Landlord for its review and written approval. Tenant shall be solely responsible for the cost of acquisition, installation, operation, and maintenance of the Generator; and Tenant shall install, maintain and operate the Generator in accordance with all federal, state, and local laws, statutes, ordinances, rules and regulations, including without limitation, obtaining and maintaining any and all permits, approvals and licenses required to install and operate the Generator by any governmental authority having jurisdiction. Landlord and Tenant agree that, upon the expiration of earlier termination of the Lease Term, Tenant shall not be required to remove the Generator, any associated cabling, wiring and screening or other improvements. Tenant shall not be entitled to grant or assign to any third party (other than a permitted assignee of Tenant’s rights under the Lease or a permitted subtenant relative to the Premises (or a portion thereof)) the right to use the Generator without Landlord’s prior written consent (which consent may be granted or withheld in Landlord’s discretion). Upon reasonable advance notice to Tenant (and provided Landlord reasonably coordinates with Tenant and provides an alternate source of backup generator capacity during said transition), Landlord shall be entitled to cause the Generator to be moved to another location near the Building, at Landlord’s cost and expense. Tenant shall pay all personal property taxes on the Generator. Tenant shall also pay any increases in the real property taxes of the Building due to the installation of the Generator within thirty (30) days of receipt of notice from Landlord which includes proof of such increase in taxes. Tenant’s indemnity obligations under Section 5.4.1.5 of the Lease, relating to the use of Hazardous Materials, shall apply to the use and operation of the Generator. Finally, Tenant’s insurance obligations under Section 10.3 of the Lease shall apply to the Generator.

  • HEATING, VENTILATING AND AIR CONDITIONING General Office Area: The building shall be equipped with a combination heating, ventilation and air conditioning system. The system shall have ducted supply and return air. The space above the ceiling shall not be used as a supply or return plenum. The systems shall be sized in accordance with the weather conditions identified in Chapter 13, “Energy Conservation” of the 1996 BOCA Building Code and supplemented by the “Building Code Rules”. All HVAC equipment shall be commercial or light industrial grade. If new construction it shall be installed at grade or within mechanical rooms for easy access and maintenance. If existing construction, roof mounted equipment will be considered after all other options have been exhausted, including the elimination of noise and vibration transfer to the structural members. The HVAC systems shall be zoned, with units sized and placed as required by heating and cooling loads on the building. Zoning of systems is dependent on the size, shape and orientation of the building. The HVAC system shall be divided into a minimum of 4 exterior and 1 interior temperature control zones. Return air shall be taken from the area supplied or adjacent to the area in the same temperature control zone. The ventilation and exhaust system shall be sized to maintain a positive pressure throughout the building envelope to limit air and dust infiltration. No HVAC ductwork shall be installed under the floor slab or underground.

  • Heating and Air Conditioning Tenant shall not use any method of heating or air-conditioning, other than that supplied by Landlord, without Landlord’s prior written consent.

  • Emergency Generator Although Landlord is the owner of emergency generator and related automatic transfer switches serving the Building and the 901 Building (collectively, the “Emergency Generator”), prior to the date of this First Amendment, Tenant, as the sole tenant of the Building and the 901 Building, has been operating and maintaining the Emergency Generator. Tenant shall, on the date that is 1 day after the mutual execution and delivery of this First Amendment by the parties (“EG Transfer Date”), (x) deliver the Emergency Generator to Landlord in good working order with a full tank of diesel (y) assign to, transfer and deliver to Landlord all governmental permits and licenses (to the extent such permits and licenses are assignable), if any, warranties (to the extent assignable), operating and maintenance manuals, records and other documents concerning the Emergency Generator, and (y) terminate any service, maintenance or other contracts maintained by Tenant with respect to the Emergency Generator. Tenant has not been obligated to maintain a wastewater permit in connection with the Emergency Generator. With respect to any permit required for the Emergency Generator, Landlord acknowledges and agrees that Tenant has been in the process of obtaining a generator permit in connection with a Tenant permitting process underway with the Bay Area Air Quality Management District (“BAAQMD”) for the 901 Building, that Tenant will remove the generator from its permit application with BAAQMD, and that Landlord will need to obtain a generator permit from BAAQMD in its own name. To the best of Tenant’s knowledge, Tenant does not have any other permits in connection with the Emergency Generator. To the extent Tenant has current contracts with any vendors for the Emergency Generator, Tenant and Landlord shall reasonably cooperate to assign or terminate such contracts in the manner set forth in Section 14 above regarding utilities. To the extent it is not possible for Tenant to remove the request for a generator permit from its BAAQMD application or to assign or terminate any service maintenance or other contracts within 1 day after the mutual execution and delivery of this First Amendment, Tenant shall not be in default hereunder if Tenant promptly commences efforts to do so and diligently performs until such actions have been completed within a reasonable period after such date. Landlord shall, within 5 days of the EG Transfer Date, as part of Expenses, conduct such testing of the Emergency Generator required, in Landlord’s sole and absolute discretion, to determine whether the Emergency Generator is, in fact, in good working order. If such testing discloses that the Emergency Generator is not in good working order, Landlord shall have the right, at Tenant’s sole cost and expense, to perform any maintenance and/or repairs required to put the Emergency Generator in good working order. Following the EG Transfer Date, Landlord’s sole obligation for either providing emergency generators or providing emergency back-up power to Tenant shall be: (i) to provide emergency generators with not less than the current capacity of the Emergency Generator and Tenant shall be entitled to Tenant’s share of the capacity thereof available for use by all tenants of the Building and the 901 Building, collectively, in accordance with the rentable area of the Premises and the 901 Building and the collective rentable areas of the Building and the 901 Building occupied by such other tenants, (ii) to contract with a third party to maintain the emergency generators (“Emergency Generator Servicer”) as per the manufacturer’s standard maintenance guidelines, and (iii) to obtain and maintain licenses for the emergency generators as required by applicable law. Landlord shall have no obligation to provide Tenant with operational emergency generators or back-up power or to supervise, oversee or confirm that the Emergency Generator Servicer or any other third party maintaining the emergency generators is maintaining the generators as per the manufacturer’s standard guidelines or otherwise. Landlord shall provide to Tenant copies of any reports received by Landlord from the Emergency Generator Servicer regarding its maintenance and repairs of the emergency generators; provided, however, that in no event shall Landlord’s failure to deliver such reports constitute a default by Landlord under the Lease. During any period of replacement, repair or maintenance of the emergency generators when the emergency generators are not operational, including any delays thereto due to the inability to obtain parts or replacement equipment, Landlord shall have no obligation to provide Tenant with an alternative back-up generator or generators or alternative sources of back-up power. Tenant expressly acknowledges and agrees that Landlord does not guaranty that such emergency generators will be operational at all times or that emergency power will be available to the Premises when needed. Landlord shall provide Tenant with not less than five (5) business days’ notice of the scheduled disruption in the operation of the emergency generators. In the case of an emergency, Landlord shall provide Tenant with notice of any emergency disruption as soon as reasonably possible after Landlord becomes aware of the need for such emergency disruption.