Minimum Equipment Requirements Sample Clauses

Minimum Equipment Requirements. Customer shall maintain certain minimum equipment and software to receive the Internet Service (see xxx.xxxxxxxx.xxxxxxxx.xxx for the current specifications). The minimum configuration standards may change, and Spectrum will make reasonable efforts to support previously acceptable configurations; however, Spectrum is not obligated to continue to provide such support. Spectrum may supply Spectrum Equipment such as modems, gateways, routers, or wireless cards, for a fee, to operate the Internet Service. Spectrum reserves the right to provide service only to users with Spectrum-approved equipment. Customer acknowledges that such Spectrum Equipment may require updates and/or changes to the software resident in the Spectrum Equipment and that Customer may be required to perform such updates and/or changes. Customer hereby authorizes Spectrum to perform updates or changes, on-site or remotely from time to time as Spectrum deems necessary, in Spectrum's sole discretion. Customer will not connect any equipment, other than equipment authorized by Spectrum, to the Spectrum Network. When Spectrum installs the Internet Service, Customer will need a network interface card or adapter providing an Ethernet connection. Alternatively, Customer may connect to a networking device (commonly referred to as a router or gateway).
AutoNDA by SimpleDocs
Minimum Equipment Requirements. A MSFU shall consist of a showering unit (trailer), potable water vehicle, hand washing sinks and all peripheral equipment and trailers necessary to mobilize and support the shower unit and its personnel. Listed below are the minimum equipment requirements for a MSFU.
Minimum Equipment Requirements. The Contractor shall ensure all equipment used in the performance of the contract on County property is in good safe working order and properly maintained in order to protect the operator and the public. All equipment used by the Contractor is subject to inspection by the County’s Representative. Any equipment on site, which is deemed by the County’s Representative to be inoperable, unsafe, or improper for desired use, shall be removed from the premises by the Contractor at his/her expense the same day of theCounty’s determination. A list of equipment shall be submitted on company’s letterhead within three (3) days of contract award. The following equipment is suggested for the life of the contract:
Minimum Equipment Requirements. 15.1 For the Darlton box to be activated, Doncaster Radar must be capable of providing a radar service using either primary or secondary radar or a combination of both.
Minimum Equipment Requirements. 1. Fully self-contained unit (i.e. trailer). Must provide sufficient size and protective covering to successfully perform all duties, in all types of adverse conditions and inclement weather
Minimum Equipment Requirements. For the Bath Gap to be activated, Bristol Radar must be capable of providing a radar service using either primary & secondary radar, or secondary radar only. BRISTOL BRISTOL PART THREE
Minimum Equipment Requirements a. Units shall be equipped with a minimum of 40 berths and maximum of 48 berths per unit:
AutoNDA by SimpleDocs
Minimum Equipment Requirements. (a) Trailer, either cargo or camper style (applicable to ALL TYPES being solicited):
Minimum Equipment Requirements. (a) Clerical Support Unit and transporation vehicle(s):
Minimum Equipment Requirements.  For tubes with an internal diameter of 19.5 mm up to 25 mm, the minimum nozzle flow rate shall be 50 litre/min at 1 000 bar working pressure. For tubes with an internal diameter between 15 and 19.5 mm the minimum nozzle flow rate shall be of 34 litre/min at 1 000 bar working pressure.  Rotating tube cleaning nozzles with multiple water jets shall be used. The cleaning nozzles shall be obtained from a recognised HPWJ equipment supplier and technical datasheets, providing technical information for a range of nozzle sizes, shall be available for the all types of nozzles used on site.  A technical data sheet shall be provided for the HPWJ pumps. The HPWJ pump shall maintain a minimum continuous working pressure of 1 000 bar at a flow rate of 50 litre/minute. This requirement assumes one pump will supply one cleaning nozzle. If a single pump is to supply more than one nozzle simultaneously, the pump shall maintain a minimum continuous working pressure of 1 000 bar and a minimum volume flow of 50 (litre/min) per each of the cleaning nozzles attached simultaneously to the pump.  At least two types of cleaning nozzles shall be available, one for unplugging tubes and the other type specifically designed to remove deposits on the tube walls. The cleaning nozzle datasheets supplied as per section 4.5 with the tender shall detail the design features of the cleaning nozzles for unplugging tubes and removing deposits from the tube walls.  The nozzles shall travel the full length of all the tubes.  HPWJ flexible hose from the foot valve to the tube cleaning nozzle shall have a minimum internal diameter of 5 mm. The maximum hose length is the condenser tube length plus an additional 7 m. The foot valve shall be positioned in the water box.  The flexible hose from the pump outlet to the foot valve shall have a minimum internal diameter of 10 mm.  Provision of a reasonable set / number of spare equipment and tooling particularly nozzles, hoses, couplings, all wear and tear parts such as seals etc. These spares shall be available on site. In the event of HPWJ Pump breakdown then repair or suitable replacement shall be affected within 2 hours. The latter shall only apply to eventualities involving unexpected major breakdown of HPWJ Pumps.  Provision of a suitable guide tube device to ensure no damage to the tube sheet coating or tube ends.  Endoscope / Fiberscope to be supplied by the Contractor to be used for post cleaning inspection. The fibre scope shall have a ...
Time is Money Join Law Insider Premium to draft better contracts faster.