MONITORING OF OPERATION AND MAINTENANCE. 19.1 Monthly status reports
MONITORING OF OPERATION AND MAINTENANCE. 19.1 Monthly status reports
1. The above provisions set out in 19.1 shall cover additional work(s) created under the provisions 16.3.2.
MONITORING OF OPERATION AND MAINTENANCE.
19.1 Monthly status reports During Operation Period, the Concessionaire shall, no later than 7 (seven) days after the close of each month, furnish to the Concessioning Authority and the Independent Engineer a monthly report stating in reasonable detail the condition of the Project including its compliance or otherwise with the Maintenance Requirements, Maintenance Manual, Maintenance Programme and Safety Requirements, and shall promptly give such other relevant information as may be required by the Independent Engineer. In particular, such report shall separately identify and state in reasonable detail the defects and deficiencies that require rectification.
MONITORING OF OPERATION AND MAINTENANCE. 17.1 Quarterly status reports
17.1.1 During Concession Period, the Concessionaire shall, no later than 7 (seven) days after the close of each quarter, furnish to the Authority and the Independent Engineer(s) a quarterly report stating in reasonable detail the condition of the Project Facilities including its compliance or otherwise with the Maintenance Requirements, Maintenance Manual, Maintenance Programme and Safety Requirements, and shall promptly give such other relevant information as may be required by the Independent Engineer(s). In particular, such report shall separately identify and state in reasonable detail the defects and deficiencies that require rectification.
MONITORING OF OPERATION AND MAINTENANCE. 48 ARTICLE 14 FORCE MAJEURE 49 ARTICLE 15 BREACHES/SURRENDER/TERMINATION OF LICENSE AGREEMENT 51
MONITORING OF OPERATION AND MAINTENANCE. Monthly status reports
20.1.1 During Operation Period, the Licensee shall, no later than 7 (seven) days after the close of each month, furnish to the Licensor and the PMC a monthly report stating in reasonable detail the condition of the Project including its compliance or otherwise with the Maintenance Requirements, Maintenance Manual, Maintenance Programme and Safety Requirements, and shall promptly give such other relevant information as may be required by the PMC or the Licensor. In particular, such report shall separately identify and state in reasonable detail the defects and deficiencies that require rectification.
MONITORING OF OPERATION AND MAINTENANCE. 19.1 Inspection and measurement of Performance Standards
19.1.1 The Technical Auditor shall inspect the Project Facilities at least once in a month and measure the compliance of the Operator with the Performance Standards. It shall make a report of such inspection (the “Inspection Report”) stating in reasonable detail the defects or deficiencies, if any, with particular reference to the Maintenance Requirements, the O&M Plan and Safety Requirements, and send a copy thereof to the Authority and the Operator within 7 (seven) days of such inspection. The Operator shall render such assistance and co-operation as may be reasonably required by the Technical Auditor to conduct such inspections.
MONITORING OF OPERATION AND MAINTENANCE. Status reports
19.1.1 During Operation Period, the Concessionaire shall, no later than 7 (seven) days after the close of each month, furnish to the Authority and the Monitoring Agency a monthly report, in the format specified in Annexure I to Schedule 19, stating in reasonable detail the condition of the Hospital, including its compliance or otherwise with the Maintenance Requirements and the Safety Requirements, and shall promptly give such other relevant information as may be required by the Monitoring Agency. In particular, such report shall separately identify and state in reasonable detail the defects and deficiencies that require rectification.
19.1.2 On the first day of every month, the Concessionaire shall, subject to Applicable Law, send to the Authority, the Clinical Panel and any entity as may be specified by the Authority, a report (in a mutually agreed form) for the previous month, stating the following:
(a) particulars of Select Patients, such as name, age and sex; and
(b) copies of the relevant medical records and prescriptions applicable to Select Patients. On the first day of each week, the Concessionaire shall, send to the Authority and the Monitoring Agency, by facsimile or e-mail, a report in a pre-agreed format, stating all accidents and unusual occurrences on the Hospital relating to the safety and security of the Patients, visitors and staff and the Hospital in the preceding week. A monthly summary of such reports shall also be sent within 3 (three) days of the closing of each month. For the purposes of this Clause 19.2, accidents and unusual occurrences in the Hospital shall include:
(a) death or injury to any person on account of any accident occurring within the Hospital premises including but not limited to a fire in the Hospital premises;
(b) episode of sexual assault or rape;
(c) suicide by a Patient;
(d) unanticipated death of a full-term infant;
(e) infant abduction or discharge to the wrong family;
(f) haemolytic transfusion reaction involving administration of blood or blood products having major blood group incompatibilities;
(g) surgery on the wrong Patient or wrong body part;
(h) smoke or fire;
(i) unintended retention of a foreign object in the body of any Patient after surgery or other procedure; and
(j) such other relevant information as may be reasonably required by the Authority or the Monitoring Agency.
MONITORING OF OPERATION AND MAINTENANCE. Monthly status reports During Operation Period, the Concessionaire shall, no later than 7 (seven) days after the close of each month, furnish to the Authority and the Independent Engineer a monthly report stating in reasonable detail the condition of the Project Highway including its compliance or otherwise with the Maintenance Requirements, Maintenance Manual, Maintenance Programme and Safety Requirements, and shall promptly give such other relevant information as may be required by the Independent Engineer. In particular, such report shall separately identify and state in reasonable detail the defects and deficiencies that require rectification. Inspection The Independent Engineer shall inspect the Project Highway at least once a month. It shall make a report of such inspection (the “O&M Inspection Report”) stating in reasonable detail the defects or deficiencies, if any, with particular reference to the Maintenance Requirements, Maintenance Manual, the Maintenance Programme and Safety Requirements, and send a copy thereof to the Authority and the Concessionaire within 7 (seven) days of such inspection. Tests For determining that the Project Highway conforms to the Maintenance Requirements, the Independent Engineer shall require the Concessionaire to carry out, or cause to be carried out, tests specified by it in accordance with Good Industry Practice. The Concessionaire shall, with due diligence, carry out or cause to be carried out all such tests in accordance with the instructions of the Independent Engineer and furnish the results of such tests forthwith to the Independent Engineer. One half of the costs incurred on such tests, and to the extent certified by the Independent Engineer as reasonable, shall be reimbursed by the Authority to the Concessionaire. Remedial measures The Concessionaire shall repair or rectify the defects or deficiencies, if any, set forth in the O&M Inspection Report or in the test results referred to in Clause 19.3 and furnish a report in respect thereof to the Independent Engineer and the Authority within 15 (fifteen) days of receiving the O&M Inspection Report or the test results, as the case may be; provided that where the remedying of such defects or deficiencies is likely to take more than 15 (fifteen) days, the Concessionaire shall submit progress reports of the repair works once every week until such works are completed in conformity with this Agreement. The Independent Engineer shall require the Concessionaire to carr...
MONITORING OF OPERATION AND MAINTENANCE. 68 ARTICLE 20. INDEPENDENT ENGINEER 70 ARTICLE 21. FINANCIAL CLOSE 73 ARTICLE 22. CONSSESION FEE 74