SECURITY AND PROTECTION FACILITIES INSTALLATION Sample Clauses

SECURITY AND PROTECTION FACILITIES INSTALLATION. 1 Contractor is responsible for security of buildings and grounds within the ‘Limits of Work’ involved in this Project, including other subcontractors and County facilities, during entire time of Contract. Make good all damages to work and loss of materials due to vandalism or theft, within this responsibility.
AutoNDA by SimpleDocs
SECURITY AND PROTECTION FACILITIES INSTALLATION. Protection of Existing Facilities: Protect existing vegetation, equipment, structures, utilities, and other improvements at Project site and on adjacent properties, except those indicated to be removed or altered. Repair damage to existing facilities.
SECURITY AND PROTECTION FACILITIES INSTALLATION. A. Environmental Protection: Provide protection, operate temporary facilities, and conduct construction in ways and by methods that comply with environmental regulations and that minimize possible air, waterway, and subsoil contamination or pollution or other undesirable effects. B. Temporary Erosion and Sedimentation Control: Provide measures to prevent soil erosion and discharge of soil-bearing water runoff and airborne dust to adjacent properties and walkways, according to requirements of authorities having jurisdiction.
SECURITY AND PROTECTION FACILITIES INSTALLATION. A. Protection of Existing Facilities: Protect existing vegetation, equipment, structures, utilities, and other improvements at Project site and on adjacent properties, except those indicated to be removed or altered. Repair damage to existing facilities. B. Security Enclosure and Lockup: Install temporary enclosure around partially completed areas of construction. Provide lockable entrances to prevent unauthorized entrance, vandalism, theft, and similar violations of security. Lock entrances at end of each work day.‌ C. Barricades, Warning Signs, and Lights: Comply with requirements of authorities having jurisdiction for erecting structurally adequate barricades, including warning signs and lighting. D. Temporary Egress: Maintain temporary egress from existing occupied facilities as indicated and as required by authorities having jurisdiction.
SECURITY AND PROTECTION FACILITIES INSTALLATION. A. Environmental Protection: Provide protection, operate temporary facilities, and conduct construction in ways and by methods that comply with environmental regulations and that minimize possible air, waterway, and subsoil contamination or pollution or other undesirable effects. 1. Comply with work restrictions specified in Division 1 Section "Summary." B. Tree and Plant Protection: Install temporary fencing located as indicated or outside the drip line of trees to protect vegetation from damage from construction operations. Protect tree root systems from damage, flooding, and erosion. C. Security Enclosure and Lockup: Install substantial temporary enclosure around partially completed areas of construction. Provide lockable entrances to prevent unauthorized entrance, vandalism, theft, and similar violations of security. 1. Maintain the security alarm system within the building as operational. Provide 24-hour per day security personal during times when the existing system is rendered inoperable due to construction or demolition work. D. Barricades, Warning Signs, and Lights: Comply with requirements of authorities having jurisdiction for erecting structurally adequate barricades, including warning signs and lighting.
SECURITY AND PROTECTION FACILITIES INSTALLATION. A. Protection of Existing Facilities: Protect existing vegetation, equipment, structures, utilities, and other improvements at Project site and on adjacent properties, except those indicated to be removed or altered. Repair damage to existing facilities. 1. Provide and maintain, for the duration of the Contract, all security precautions and proper protective measures as may be required to adequately protect the Owner's personnel, the public, and other interests of the Owner, from hazards resulting from, or related to, the work performed hereunder. When regulated by local building code or other Authority, the requirements of this Paragraph 3.4 shall be considered as minimum requirements and the Contractor shall be responsible for the protection of such minimum requirements as may be required by public safety laws. 2. Take all proper precautions to protect the Owner's property from damages and replace or put in good condition, any existing items which are damaged in carrying out the work, unless designated to be permanently removed or demolished. 3. Bear full responsibility for adequately patrolling and protecting the work under construction and the materials stored on the site. 4. The requirements of this paragraph 3.4 shall be in addition to, not in lieu of, other protection requirements contained in these Contract Documents. 5. Furnish, erect, and maintain, until such time as removal is approved by the Architect, temporary fencing, to be located immediately within the Limit of Work lines, and barricades to the extent recommended by OSHA and as otherwise required for the protection of life and property during operations under the Contract. 6. Construct barricades and protective facilities in accordance with local and State regulations. Furnish and install all signs, lights, reflectors, and all such protection facilities as may be required. 7. Bear full responsibility for saving the Owner harmless from all claims arising from the use of public streets, sidewalks, and adjoining premises for construction purposes. 8. Keep all access roads and walks clear of debris, materials, construction plant and equipment during building operation. Repair streets, drives, curbs, sidewalks, fences, poles and the like where disturbed during the construction operations, and leave them in as good condition after completion of the work as before operations started. 9. Protect all utilities and site improvements not otherwise designated to be removed under this Contract. 10. Bea...
SECURITY AND PROTECTION FACILITIES INSTALLATION. A. Protection of Existing Facilities: Protect existing vegetation, equipment, structures, utilities, and other improvements at Project site and on adjacent properties. Repair damage to existing facilities. 1. Where access to adjacent properties is required in order to affect protection of existing facilities, obtain written permission from adjacent property owner to access property for that purpose. B. Security Enclosure and Lockup: Install temporary enclosure around partially completed areas of construction. Provide lockable entrances to prevent unauthorized entrance, vandalism, theft, and similar violations of security. Lock entrances at end of each workday.
AutoNDA by SimpleDocs
SECURITY AND PROTECTION FACILITIES INSTALLATION. A. Temporary Construction Fence: Install and maintain 6 foot tall chain link construction fence. Posts to be driven or set on bases. Posts are not to be driven into any pavement designated to remain.
SECURITY AND PROTECTION FACILITIES INSTALLATION. A. Environmental Protection: Provide protection, operate temporary facilities, and conduct construction in ways and by methods that comply with environmental regulations and that minimize possible air, waterway, and subsoil contamination or pollution or other undesirable effects. Avoid using tools and equipment that produce harmful noise. Restrict use of noisemaking tools and equipment to hours that will minimize complaints from persons or firms near Project site. B. Tree and Plant Protection: Install temporary fencing located as indicated or outside the drip line of trees to protect vegetation from construction damage. Protect tree root systems from damage, flooding, and erosion. C. Barricades, Warning Signs, and Lights: Comply with standards and code requirements for erecting structurally adequate barricades. Paint with appropriate colors, graphics, and warning signs to inform personnel and public of possible hazard. Where appropriate and needed, provide lighting, including flashing red or amber lights.
SECURITY AND PROTECTION FACILITIES INSTALLATION. A. Except for use of permanent fire protection as soon as available, do not change over from use of temporary security and protection facilities to permanent facilities until Substantial Completion. B. Temporary Fire Protection: Until fire protection needs are supplied by permanent facilities, install and maintain temporary fire protection facilities of the types needed to protect against predictable and controllable fire losses. 1. Locate fire extinguishers where convenient and effective for their intended purpose. 2. Store combustible materials in fire-safe locations. 3. Maintain unobstructed access to fire extinguishers, fire hydrants, temporary fire protection facilities, stairways and other access routes for fighting fires. Prohibit smoking in hazardous fire exposure areas. 4. Provide supervision of welding operations, combustion type temporary heating units, and similar sources of fire ignition.
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!