Basis of Design Report. ‌ 45 Developer shall prepare a Basis of Design Report for the Project that includes, at a minimum,
AutoNDA by SimpleDocs
Basis of Design Report a.) Provide as defined in the TSA PGDS Version 4.1 the required Basis of Design documents to include: b.) Electrical requirements and distribution
Basis of Design Report. (BODR) Following the Alternatives Analysis, prior to commencing the design, The Design/Builder’s Team will establish the design criteria for the Project. The criteria will be reviewed by and discussed with The City of Bend. The mutually agreed upon design criteria will be documented in a Basis of Design Report (BODR). The BODR will include: • Hydraulic Profile • Influent Flow Control Structure site locationForce main alignment including identification of trenchless sections • Code and standard reference requirementsStructural design criteria • Anticipated electrical service and required coordination with utility companyA list of required permits and ROW/Easement acquisition • Schedule for design through GMP Level documents TASK 3 – TECHNICAL EXHIBITS For the selected Influent Flow Control Structure configuration and Force Main alignment (10,500 linear feet), and upon written authorization from The Design/Builder will prepare Technical Exhibits to facilitate development of GMP. The Technical Exhibits will consist of drawings prepared in AutoCad 2016 (2D format) and specifications prepared in Microsoft Word. • The Sheet List Table provides the list of drawings included in this scope of work. • Technical Specifications sections will include: concrete mix design; pipeline material; trenchless construction; and pumps (mechanical and related electrical specifications). Other material and requirements will be noted in the drawings. • Pipeline drawings will include plan and profiles at 1-inch equals 40 feet scale horizontally and 1-inch equals 4 feet vertically. • City standard specifications and details will be incorporated as necessary. • XxXxxxxx Xxxxxx, as a subconsultant to The Design/Builder, will provide design for the trenchless segments • The Design/Builder will prepare Traffic Control plans (total 3 sheets)
Basis of Design Report. Allow the City to select the preferred strategies for controlling odor and corrosion. Prepare a Basis of Design Report that identifies the proposed treatment systems and required equipment including, at a minimum, conceptual site layouts, treatment configurations, sizing and capacity of treatment equipment (including the specific manufacturer system model), sizing and capacity of needed plumbing (i.e. water service, process drains, and chemical feed lines), injection rates, types of specific chemicals, electrical service ratings for recommended equipment, telemetry parameters, instrumentation, and integration compatibility. Identify additional engineering studies, if any, that may be required as part of the preliminary engineering and/or 30% design stage. Issue a draft report, incorporate City comments, and issue a final report. Deliverables • Draft Basis of Design Report (5 hard-copies, electronic PDF and MSWord files) • Final Basis of Design Report (5 hard-copies, electronic PDF and MSWord files)
Basis of Design Report. The Design Professional will prepare a Basis of Design Report. The Design Professional will develop the basis of Design for the project and develop consensus with the project team on the direction of the project design. Elements of study include project sequencing, avoidance of shutdowns, analysis of piping and replacement pipe sizing at the Spring Hill Complex, analysis of replacement methods at Spring Hill Complex, highlining needs and fire service replacement coordination. The basis of design will present up to two (2) conceptual design alternatives to the City for selection. A Draft Basis of Design Report will be submitted to the City for review and comment. A Final Basis of Design Report will be revised to address City comments and submitted to the City.
Basis of Design Report. (Doc:PDF, 20 Hard Copies) Technical Memorandum sif/;zmarizingfindings.
Basis of Design Report. Horizons will prepare a basis of design for the proposed improvements. This basis of design will be submitted to the State of New Hampshire Department of Environmental Services (NHDES) for review and approval prior to proceeding with final design of the individual system components. Horizons will also coordinate with the Town of Xxxxxxx to determine permitting requirements for the pump stations and atmospheric storage tank. Landowner coordination has not been included in this scope, but can be provided.
AutoNDA by SimpleDocs
Basis of Design Report. The Consultant will prepare a Project Definition Document PDD), outlining the project, design criteria for FTA and other regulatory agencyreview. The PDD will serve as the Basis of Design for submittal to the FTA.
Basis of Design Report. (BODR). The purpose of the BODR is to refine the SMA, update the CSM and refine the technology assignments to the SMA consistent with the Decision Tree in Figure 28 of the ROD. To the extent practicable, the BODR will incorporate information, evaluations and approaches developed in the Technical Evaluations Work Plan and BODR prepared under Appendix A of the Settlement Agreement. Respondent shall submit a BODR for EPA comment and approval. This document will describe the objectives, overall approach, schedule, milestone check in points and specific elements of the BODR. The BODR will: Summarize the results of the sufficiency assessment and whether potential sources of recontamination have been adequately investigated and controlled or considered such that the RA can proceed. Summarize existing site conditions and site factors which affect technology assignments including detailed reasonably anticipated future navigation and land use information and other data, as depicted in the Decision Tree, and refinement of the CSM pertaining to the Project Area; Summarize design criteria applicable to the Project Area as described in the Remedial Design/Remedial Action Handbook, EPA 540/R-95/059 (June 1995) and consistent with Section 14.2.9 (Design Requirements) and Section 14.2.10 (Performance Standards) of the ROD; Describe Decision Tree analysis and identify a preferred remedial approach, including technology assignments and Project Area specific institutional controls, based on consistency with the applicable Remedial Action Objectives (RAOs) and ROD elements for the Project Area; Identify long-term monitoring and maintenance considerations for the Project Area; Identify design studies for RD, if any, such as subsurface and surface sediment sampling and benthic toxicity testing that may be needed to evaluate attainment of applicable RAOs and address proposed remedial technology means and methods, and gather other information necessary for RD for the Project Area; and Describe a sequencing plan as well as an overall schedule to complete the design studies, RD and RA for the Project Area.
Basis of Design Report. Basis of design will consist of a tech memo that documents the following items: • Summary of City provided 3-years of sludge press loading and thickening data • Design for two Sludge Press Manufacturers and allow “or equal” if there is a manufacturer that can meet the same operational requirements. If none is determined to be an equal then only one manufacturer will be listed. • Electrical Power requirements • Verify required utilities for BFP operation Verify dimensions needed for BFP installation and maintenance • Required piping modifications • Permitting Requirements